Parameter
Description
ResDst
Select the resolution in mm for the distance output value via the digital
data interface. The output value corresponds to the measured value [mm]
divided by the selected resolution. The parameter does not have any influ‐
ence on the measured value shown on the display.
Prerequisite: The parameter is only displayed if the
Yes
option is selected for
the
more
parameter.
Options
•
0.1 [mm]
•
0.125 [mm]
•
1.0 [mm]
•
10.0 [mm]
•
100.0 [mm]
•
freRes
Factory setting
•
0.1 [mm]
freRes
Select resolution in μm (micrometer) if the
freRes
value was selected in the
ResDst
parameter.
Options
•
1 ... 100,000 [μm]
Factory setting
•
100 [μm]
ResSpd
Select the resolution in mm/s for the speed output value via the digital data
interface. The output value corresponds to the measured value [mm/s] div‐
ided by the selected resolution. The parameter does not have any influence
on the measured value shown on the display.
Prerequisite: The parameter is only displayed if the
Yes
option is selected for
the
more
parameter.
Options
•
0.1 [mm/s]
•
1.0 [mm/s]
•
10.0 [mm/s]
•
100.0 [mm/s]
•
freRes
Factory setting
•
1.0 [mm/s]
freRes
Select the resolution in μm/s (micrometers per second) if the value
freRes
was selected in the
ResSpd
parameter.
Options
•
1 ... 100,000 [μm/s]
Factory setting
•
1,000 [μm/s]
7.1.6
more? menu
In the
more?
menu, you can activate or deactivate the advanced menu view.
OPERATION
7
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
37