The FLOWSIC100 Flare can also be fitted with an optional spool piece to reduce geometric
uncertainty of device installation and to simplify assembly. The exact design (nominal
diameter, connection, material) always depends on the customer specifications.
The installation length of the spool piece depends on the nominal diameter of the pipe:
– Installation length 800 mm for pipe diameter up to 28”
– Installation length 1100 mm for pipe diameter 30” ... 60”
– Installation length for pipe diameter >60”...72” on request
All system solutions (FLOWSIC100 Flare + spool piece) are optionally available with
pressure and temperature sensors. For the positioning of pressure and temperature
transmitters the following configurations are available:
– Measuring tube with standard installation length with integrated pressure tapping, tem
-
perature sensor 5 D
T
( = 5 * diameter of the thermowell) in the outflow area (customer's
pipeline)
– Spool Piece, extended length with integrated pressure and temperature tapping.
Fig. 10
Spool piece option (example)
3.5
Transport and storage
Comply with permissible storage conditions (
).
3.5.1
Transport protection
To prevent transport damage, the FLSE100-XT sender/receiver units must be secured
according to Fig. 11 before each transport.
▸
Retract the transducer fully into the retraction nozzle.
▸
Ensure in a suitable manner that the transducer cannot slip out of the retraction nozzle
during transport.
800 mm