8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
17
Information Before Use
3.4
Installation
3.4.1
Notes for installation
When you install this product, ensure that there is sufficient space around
the product in order to prevent overheating.
Space between sensors
40 mm or more
Space required
above the sensor
40 mm or more
Laser exposure
direction
Laser exposure
direction
The Profiler 2 performs measure-
ments by emitting a parallel laser
beam and receiving the reflected
light.
During measurement, ensure that
the laser beam and reflected light
is not blocked by the target object.
迷光
Stray light
Before using the product, check
that stray light, which is reflected
by a wall or by highly reflective
objects, does not have an effect
on the measurements.
3.4.2
Installing the Sensor
1. Insert the included mounting screws (two M4 × 50 mm screws)
into the mounting holes to temporarily affix the sensor to a location
that is roughly in the desired location.
2. Measure the distance between the sensor and the detection
target object. Please make sure the measuring object is within the
measuring area.
3. Adjust the sensor position on the basis of the measurement result,
and then use the included nuts and washers to fix the screws in place.