8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
123
Serial Communication
Function
Set or
acquire
Send
or
reply
Length Command
(hex)
Data string
Parameter
Tilt cor pos
Set
Send
1
4019
aaaa
aaaa: Tilt correction reference position
-7499 to +7500 (×2)
Reply
0
—
Acquire Send
0
401a
—
Reply
1
aaaa
Save
master
Register Send
0
401b
—
Register the current profile as the master image.
Reply
0
Master
image
Register Send
0
0014
—
aaaabbbb: Address of the master profile (“aaaa”
is the upper part and “bbbb” is the lower part)
Reply
0
—
Acquire Send
0
0015
—
Reply
2
aaaabbbb
8.5.5
Area Settings
Function
Set or
acquire
Send
or
reply
Length Command
(hex)
Data string
Parameter
Coverage
Set
Send
5
6002
000abbbbccccdddd
eeee
a: Area
a
Setting value
a
Setting value
0
Area1
2
Area3
1
Area2
3
Area4
bbbbccccddddeeee:
a: Area
Details
Input value
bbbb Upper coordinate -13999 to +13743
cccc
Left coordinate
-7499 to +7243
dddd Lower coordinate -13743 to +13999
eeee Right coordinate -7243 to +7499
Reply
0
—
Acquire Send
1
6003
000a
Reply
4
bbbbccccddddeeee