Permissible resistivity in
a single system between
OSSD and load
≤ 2.5 Ω
Permissible resistivity in
a cascade between OSSD
and load
≤ 1 Ω
Test pulse width
130 µs ... 300 µs (typ. 150 µs)
Test pulse interval
160 ms ... 240 ms (typ. 200 ms)
Test pulse deviation
(between OSSD1 and
OSSD2)
80 ms ... 120 ms (typ. 100 ms)
Discrepancy time (offset
between switching from
OSSD2 and OSSD1 within
an OSSD pair)
≤ 1 ms
Type of output
Push-pull output
Output voltage (HIGH)
(U
V
- 2.25 V) ... U
v
Output voltage (LOW)
0 V … 2 V
Output current
≤ 200 mA
Leakage current
≤ 2 mA
Load inductance
≤ 2.2 H
Load capacity
≤ 1 µF
Control inputs (IN 1, IN 2, IN 3)
6)
Input voltage for ON state
(HIGH)
8 V ... 30 V
Input voltage for OFF state
(LOW)
-3 V ... 5 V
Input current for ON state
(HIGH)
2 mA ... 15 mA
Input current for OFF state
(LOW)
< 0.5 mA
1)
The power supply unit must be able to jumper a brief power failure of 20 ms as specified in IEC 60204-1.
Suitable power supply units are available as accessories from SICK.
Battery-powered systems must be able to jumper brief power failures of 5 ms.
2)
A fuse with a maximum rated current of 2 A (slow blow) must be installed in the isolated 24 V DC power
supply circuit to the device in order to limit the available current.
3)
The voltage level must not fall below the specified minimum voltage.
4)
Applies to the voltage range between -30 V and +30 V.
5)
The OSSDs must operate loads that require at least 2 mA each to switch to the ON state.
6)
All control inputs must be powered from the same voltage supply as the safe multibeam scanner.
Table 21: Mechanical data
Dimensions (W × H × D)
160 mm x 43 mm x 56 mm
Weight
0.17 kg
Housing material
Durabio (front part, black)
Polycarbonate (back part, colza yellow)
Housing color
RAL 9005 (black) and RAL 1021 (colza yellow)
Table 22: Ambient data
Enclosure rating
1)
IP65 (IEC 60529)
Ambient light immunity
≤ 10 klx
2)
TECHNICAL DATA
13
8025936/2021-01-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 I/O
75