10
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
10.1
Features
Variant
TiM781
Measurement principle
HDDM+
Application
Outdoor
Light source
Infrared (wavelength 850 nm, max. pulse power 880 mW, max.
pulse width 5 ns, pulse frequency 1,500 kHz)
Laser class
1 (IEC 60825-1:2014, EN 60825-1:2014)
Complies with 21 CFR 1040.10 and 1040.11 except for conform‐
ance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56
dated 8 May 2019.
Aperture angle
270° (horizontal)
Scan field flatness
Typ. ± 1.5°
Scanning frequency
15 Hz
Angular resolution
0.33°
Working range
0.05 m ... 25 m
Scanning range for 5%
remission
5 m (typical)
Sensing range for 10%
remission
8 m (typical)
1)
Distance resolution
1 mm
Spot size
Spot size on the optics cover: 7 mm
Divergence: 8.6 mrad (0.49°)
Number of echoes evalu‐
ated
1
Scan/frame rate
12195 measurement point(s)
1)
at ambient temperature < -15 °C: typ. 7.5 m
TECHNICAL DATA
10
8024231/1G72/2022-05-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM781
49
Subject to change without notice