Table 3: Operating elements and functions
Item
Function
1
Display in RUN mode: If LEDs 1 and 5 light up, no edge has been detected in the read‐
ing field or the taught-in edge has been lost.
If LED 1 on the left lights up, the edge was lost on the head side.
If LED 5 on the right lights up, the edge was lost on the male connector side.
2
To open the operating menu, press SET. Select the Edge Teach menu item.
3
Edge Teach selected. To teach-in the device, the edge must be located in the reading
field. If there are several edges in the reading field, the first edge is selected.
4
Edge has been taught in, Q1 and Q2 light up (depending on the Area Teach selected
before) if the teach-in was successful.
5
Area Teach selected. To perform an area teach-in, the edge must be located at the
desired position within the reading field, the switching zones for Q1 and Q2 are
selected in the next step.
6
Definition of the switching window around the taught-in edge: 1 LED lights up: 2 mm
switching window (Q1 switches from 2 mm before the taught-in edge position to the
end of the reading field, Q2 switches from the beginning of the reading field up to
2 mm after the taught-in edge); 2 LEDs light up: 4 mm switching window (Q1 switches
from 4 mm before the taught-in edge position to the end of the reading field, Q2
switches from the beginning of the reading field up to 4 mm after the taught-in edge);
3 LEDs light up: 8 mm switching window (Q1 switches from 8 mm before the taught-in
edge position to the end of the reading field, Q2 switches from the beginning of the
reading field up to 8 mm after the taught-in edge); 4 LEDs light up = 16 mm switching
window (Q1 switches from 16 mm before the taught-in edge position to the end of the
reading field, Q2 switches from the beginning of the reading field up to 16 mm after
the taught-in edge); 5 LEDs light up: The entire reading field becomes a switching win‐
dow.
7
Select the Sensitivity menu.
8
– Middle (standard sensitivity setting)
9
– Coarse (less sensitive, detection of clear edges)
10
– Fine (highly sensitive, defection of fine edges)
11
Select the reading direction menu:
After changing the reading direction, any previous teach-in is deleted.
12
– Male connector to head side
13
– Select by teach
14
– Head to male connector side
6.4
Additional settings via SOPAS
NOTICE
In this chapter, the operation of the sensor via the SOPAS configuration software is
described.
The SOPAS ET software can be downloaded from the following link:
www.sick.com/de/en/sopas-engineering-tool-2018/p/p367244
The driver for this product can be found at
.
6.4.1
Selecting the operating mode
The AS30 Core offers 2 possible operating modes: “Edge” and “Position”.
OPERATION
6
8022080.15LJ/2020-05-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | AS30 Core
23