COMMISSIONING
6
83
8020776/12AX / 2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S |Free Flow Profiler
6.6.2
Configuring system functions for vehicle detection
6.6.2.1
Defining the position and rotation of the 2D LiDAR sensors
Define the exact positions of the sensor components used for vehicle detection on the
gantry. The values entered must be based on the zero-point of the coordinate system.
The
LMS
Axle must be in the same Z-plane as the LMS Width.
Roughly aligning components
Provisionally align the sensor components in the graphical display of the live view.
1. Click on a component in the live display.
2. Click on the component again and keep the mouse button pressed. A grid appears to
serve as a guide.
3. Now move the component to the relevant plane.
The orientation of the grid will automatically adapt to the current perspective of the live
view. Rotate the measurement site in the live view to switch between displaying the grid
along the X-axis and the Z-axis, respectively.
Note
Note