4
GETTING STARTED
58
8024172/V3-0/2021-01|SICK
Oper at i ng i ns t r uc t i ons | LABEL CHECKER P6XX
Subject to change without prior notice.
4.7.2
Mask region
The masked region is subtracted from the object locator region, where the resulting mark
will not contain edges from the mask region. This action is most favorable in eliminating
any changes in text or character print of the label sample.
Maximum rotation - Maximum rotation sets the rotation interval and restricts the
range of rotation of a searched object.
Minimum match - match setting tells how well the located object must match.
The match score can be set between 0.05 (lower value) to 0.95 (higher value).
4.7.3
Search area region
Defines the region of interest where the object is searched within the area of the object
locator. The search area can easily be adjusted/resized which creates faster search
inspection. Only the center of the shape must be located within the search area, in order
for the algorithm to find it.
4.7.4
Region shape
Shape type is a geometric shape of a region and is placed where we execute a reading.
The characters are identified within this shape region.
Supported region shapes are the following:
Figure 29 Region shape