![SICK 1086947 Operating Instructions Manual Download Page 54](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314054.webp)
4
GETTING STARTED
54
8024172/V3-0/2021-01|SICK
Oper at i ng i ns t r uc t i ons | LABEL CHECKER P6XX
Subject to change without prior notice.
4.7.1
Object locator region
When the add locator is enabled, the object locator will teach the camera to identify a
specific mark. The selected object region will then act as a reference point to orient and
assist the camera during processing.
Figure 24 Object locator region
Matching robustness
Controls the accuracy in locating the components. Where values range from 1 to 6:
Option 1
No specific parameters to set. Easy to use – fast option but for well-defined
shapes only.
Figure 25 Option 1 SICK speed & robustness
Option 2
Parameters: Edge threshold, downsample factor, and scale factor.
Figure 26 Option 2 Advanced SICK Speed & robustness