4.11.1
Pixel counter
Required intensity threshold
Sets the minimum and maximum pixel intensity.
Area ratio
Area coverage to be evaluated.
Area ratio with required intensity
Area ratio [%] with required intensity specifies the range of coverage to be
evaluated as OK.
Pixel count
Counts the number of pixels.
Count of pixels with required intensity
Pixel count with required intensity specifies the range of coverage to be
evaluated as OK.
Please be informed that Green color highlight indicates that ROI is detected, and red
indicates unfavorable ROI inspection.
Figure 79 Pixel counter inspection comparison
Please be informed that you must be a “Service” level user in order to access the Pixel
counter.