4.9.3
Specify number of characters
The value of the desired 1D code characters can be set or changed simply through
adjusting the slider.
4.9.4
Quality check
Inspects the print quality of 1D/2D code. The result can be affected by external influences
such as ambient light, reflections, etc., so it is necessary to ensure stable and the best
possible conditions for reliable quality recognition.
Minimum quality required
Equivalent to OCR/OCV minimum confidence. If the quality check was enabled, then the
printing quality of read 1D code is determined and compared to the required minimum
quality. Higher printing quality presents positive result.
4.9.5
1D code reading type
Figure 76 Type of 1D code reading
Code recognition
Use code recognition when you only need to read the code.
Code verification
Use code verification when the code is already known, and you only need to validate the
legibility.
If the code verification is selected, then you can select whether the expected text is kept
or decreased/increased by one, after one inspection is executed. The expected text must
be a number; when increasing or decreasing the value.
When the Code Verification is selected, then the expected text is matched to a recognized
(read) text.
If the expected text is equal to read text, then the result of the inspection is positive,
otherwise negative.