S300 with firmware < 02.10 and serial number < 12210000
°
S300 with system plug serial number < 12210000
°
S3000 Professional CMS
°
S3000 with firmware < B02.41 and serial number < 12210000
°
S3000 Standard, Advanced, Professional with an I/O module with serial num‐
ber < 12210000
°
S3000 Remote with an I/O module with serial number < 11240000
•
You are configuring an S300 with firmware < 02.10 and serial num‐
ber < 12210000.
•
You are configuring an S300 with system plug serial number < 12210000.
•
You are using a safety laser scanner with a system plug in which a configuration is
saved that:
°
only supports the compatibility mode.
°
was configured in the compatibility mode.
°
was configured with a CDS version < 3.6.7.
•
You want to ensure newly configured devices can be replaced with old devices.
•
You want to replace old devices with new.
The table below shows the differences between the functions of the device variants in
the compatibility mode.
Table 12: Functions in the compatibility mode
Functions
Standard
Advanced
Professional
Expert
Application diagnostic output “Warn‐
ing field interrupted”
C
C
C
C
Application diagnostic output “Error/
contamination”
C
C
C
C
Application diagnostic output “Reset
required”
C
C
C
C
External device monitoring (EDM)
C
C
C
C
C
C
C
C
Field sets comprising a protective
field and one warning field
1
2
4
8/4
1)
Programmable monitoring cases in
stand-alone operation
1
2
4
8
Speed routing using a Flexi Soft
safety controller
–
–
–
–
1)
Eight field sets at 1.0° angular resolution; four field sets at 0.5° angular resolution.
NOTE
•
The user interface of the CDS in compatibility mode corresponds to the user inter‐
face of CDS version 3.6.6.
•
The related operating instructions delivered with the device are to be used for
older devices.