Parameter
Factory settings
Time for delay mode:
0000 ms ... 9,999 ms
100 ms
8.4.2
Q
2
/ Q
a
output
The Q
2
/ Q
a
output can be configured either as an analog output or as a digital output.
8.4.2.1
Notes on the output functions
8.4.2.1.1
4-20 mA output function
If the 4-20 mA setting is selected, output 2 functions as an analog current output. The
measured value of the device is output as a proportional-linear current value that corre‐
sponds to the other device settings.
8.4.2.1.2
0-10 V output function
If the 0 - 10 V setting is selected, output 2 functions as an analog voltage output. The
measured value of the device is output as a proportional-linear voltage value that corre‐
sponds to the other device settings.
8.4.2.1.3
Digital output function
In the case of the digital output function, output 2 functions as a digital output. Since
output 1 is used exclusively for switching, this setting corresponds to the behavior of
output 1. A switching signal that corresponds to the other device settings is output
based on the current measured value.
8.4.2.1.4
Off output function
When the
Off
output function is activated, output 2 does not have any function and is
therefore deactivated.
8.4.2.2
4-20 mA analog output
>
I/O interface
>
>
Q2/Qa output
>
>
4-20 mA analog output
>
Parameter
Factory setting
Qa teach-in:
Distance (4 mA)
Distance (20 mA)
-
-
Manual Qa teach-in:
Distance (4 mA): -1,000.0 mm ... +1,000.0 mm
Distance (20 mA): -1,000.0 mm ... +1,000.0 mm
-400.0 mm
+400.0 mm
8.4.2.3
0-10 V analog output
>
I/O interface
>
>
Q2/Qa output
>
>
0-10 V analog output
>
8
OPERATION VIA DISPLAY
46
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/18JN/2020-07-01 | SICK