background image

 

 

User’s Manual  

 

2.2.1 

It consists of three LED displays of four digits each. Display function is selectable by means 
MODE pushbutton. 

For  generator  measures,  L1,  L2  and  L3  inscriptions  show  relations  between  phases  and 
functions and the display-selected function. 

The selectable modes are the followings: 

1. 

GEN-SET VOLTAGE phase to phase 

2. 

GEN-SET VOLTAGE phase to neutral 

3. 

GEN_SET CURRENT 

4. 

MAINS VOLTAGE phase to phase 

5. 

ACTIVE POWER 

6. 

BATTERY VOLTAGE / ENGINE SPEED / FREQUENCY 

7. 

GEN-SET VOLTAGE phase to phase / GEN-SET CURRENT / FREQUENCY 

Mode 2 is indicated by means the flashing of GEN-SET VOLTAGE signal. 

Mode 7 alternates the displaying of the three phase in sequence every 4 seconds. The active 
phase is indicated by the position of a dash on the fourth digit of FREQUENCY display: dash 
in upper  position for L1-L2 phases,  dash  in middle for L2-L3  and dash  in bottom for L3-L1. 
Mode is indicated by means the flashing of GEN-SET VOLTAGE, GEN-SET CURRENT and 
BATT/SPEED/FREQ. Signals. 

 

2.2.2 

This LCD display works in four different modes. If a mode has more than one page that can 
be  directly  accessed,  it  is  possible  to  scroll  between  them  by  means  the  horizontal  scroll 
pushbuttons  (left  and  right  arrows):  this  feature  is  highlighted  by  the  symbols   



and 



flashing on the upper right of the MULTIFUNCTION display. 

Display’s backlight lamp is driven by the board that switches it off if no pushbutton is pressed 
for the LAMP-SAVER time (default 30s). Lamp can be switched on pressing any key (SHIFT 
key alone too). 

The LAMP-SAVER time is programmable (menu 

AUX. FUNC. ->

 

OTHER AUX -> SCREEN 

SAVER

). 

 

 

 

 

 

 

 

 

Summary of Contents for DST4601

Page 1: ...Filename EAAM005709EN docx Rev 09 Date 06 05 2013 ID Document EAAM0057 Product DST4601...

Page 2: ...tputs 11 3 4 Engine input output terminals 13 3 5 Other connectors 13 3 5 1 JH Power Supply 13 3 5 2 JI RS232 13 3 5 3 JP and JR connector 13 4 Programming notice 14 4 1 Access code 14 4 2 How to modi...

Page 3: ...makes generation function impossible and causes the automatic generator shutdown after a proper cooling down cycle The word WARNING is used to indicate a warning that requires an operator action but...

Page 4: ...ttons Key position Function OFF RESET PROGRAM Gen set is disabled All the alarms are reset It is possible to gain access to programming function MAN Gen set is in manual mode AUTO TEST Gen set is in a...

Page 5: ...y or enables disables the change mode of a variable EXIT Brings up to the previous menu level Used together with the SHIFT pushbutton changes the fuel pump mode to manual enables disables the fuel pum...

Page 6: ...e active phase is indicated by the position of a dash on the fourth digit of FREQUENCY display dash in upper position for L1 L2 phases dash in middle for L2 L3 and dash in bottom for L3 L1 Mode is ind...

Page 7: ...ws to modify the value press ENTER to confirm or EXIT to abort To go back the previous menu press the EXIT pushbutton This mode shows by means of some different pages information about the genset oper...

Page 8: ...changed the displayed phase TEST ON or FLASHING if in TEST mode FUEL PUMP OFF fuel pump command in manual and inactive ON fuel pump command in automatic and inactive FLASHING fuel pump command in auto...

Page 9: ...le input preset to test command If driven and the key lock is in AUTO actives the TEST mode JA 07 INPUT 07 OIL PRESS ALARM Programmable input preset to a BLOCK for engine minimum oil pressure JA 08 IN...

Page 10: ...t preset to the HIGH FUEL LEVEL function The following functions can be assigned to the digital inputs Code Description 0 Not used 1 External warning 2 External disable 3 External block 4 External eng...

Page 11: ...minal Output type Function JD 21 Relay 1A N O OUTPUT 21 FUEL PUMP Programmable output preset to the function FUEL PUMP COMMAND JD 22 Relay 1A N O OUTPUT 22 FUEL ALARM Programmable output preset to the...

Page 12: ...ammable output preset to signal a block or disable dues to the generator JG 46 Open collector 350mA OUTPUT 46 SPEED ALARM Programmable output preset to signal block dues to engine speed JG 47 Open col...

Page 13: ...O NOT USE JF 33 Measure input OIL PRESSURE Input for oil pressure sensor VDO VEGLIA or optional 0 10V JF 34 Measure input W TEMPERATURE Input for coolant temperature sensor VDO VEGLIA or optional 0 10...

Page 14: ...n the menu included the password modify pages It s possible that after password input menu doesn t show all the allowed pages In this case press EXIT to go to previous menu and access again the menu a...

Page 15: ...amp identify each record The number is shown in the upper right position of multifunction display together with the total number of available records Consider that when the archive is full a new recor...

Page 16: ...keys to select LANGUAGE then press ENTER again At this point board will ask for the password If the keyed password is correct will be shown a page that allows selecting the operating language To make...

Page 17: ...t be removable without tools Safety EARTH connection must be made in a fixed way by means at least one of the dedicated terminals The generator and mains voltage lines connected to the measure inputs...

Page 18: ...18 User s Manual HOLE 5MM 240 80 80 260 70 EXAGONAL NUT 4MA SPRING WASHER 4 WASHER 4...

Page 19: ...the right to modify this document without prior notice SICES has made any effort to ensure that the information herein provide are correct in any case SICES does not assume any liability for the use t...

Reviews: