D-PRO Protection relay Technical Manual
•
Warning.
This term is used to indicate an anomaly that, under the current
circumstances, does
n’t compromise the operation of the genset: the operator should
take note of it anyway, because sooner or later it could worsen in a more serious
anomaly.
•
Alarm.
This term is used to indicate an anomaly that requires the stop of genset.
There are immediate risks for the genset, therefore it needs to be stopped
immediately.
1.6.2
AIF
It identifies a function for the configuration of the analogue inputs
(“Analogue
Input Function”). The number that follows the caption “AIF” is the code to set in
the parameter that configures the function of the desired analogue input.
AOF
It identifies a function for the configuration of the analogue outputs (“Analogue
Out
put Function”). The number that follows the wording “AOF.” is the code to
set in the parameter that configures the function of the desired analogue output.
AVF
It identifies a function for the configuration of virtual analogue inputs (“Analogue
Virtual Fun
ction”). The number that follows the wording “AVF.” is the code to
set in the parameter that configures the function of the desired analogue input.
DIF
It identifies a function for the configuration of digital inputs (“Digital Input
Function”). The number that follows the caption “DIF” is the code to set in the
parameter that configures the function of the desired digital input.
DOF
It identifies a function for the configuration with the digital outputs (”Digital
Output Function”). The number that follows the caption “DOF” is the code to set
in the parameter that configures the function of the desired digital output.
EVT
It identifies an event in the history log. The number that follows the caption
“EVT” is the numeric code of the event.
ST
It identifies a c
ontroller status (”Status”). The code the follows the caption “ST.”
indicates a status of a measurement or a condition of the device or of one of its
functions.
AL
It identifies an alarm (”Alarm”). The number that follows the caption “AL.”
indicates the alarm numeric code.
1.7
In this manual, the modifications, with respect to the previous version, are signalled by a
vertical bar on the right of the paragraphs. The modifications on the fields of a table are
highlighted with a grey background.
1.8
The software revisions will be described in different part of the manual. These revisions are
referred with the SICES code assigned to it (which is reported on a label on the controller rear
side). The code format is: EB0250247XXYY, where “XX” is the major version number and “YY”
is the minor version number. Thus, the code EB02502470100 refers to the controller software
release "1.00".
INFORMATION! In the codes above, the two letters marked with YY can be replaced
by a number indicating the version. The two final letters XX can be replaced by a
progressive number indicating the product revision or option.
Summary of Contents for D-PRO
Page 11: ...D PRO Protection relay Technical Manual 5 2...
Page 52: ......