background image

INSTRUCTION MANUAL

 · EN

7.0

9.0

6.0

Summary of Contents for SyncraSDC 6.0

Page 1: ...INSTRUCTION MANUAL EN 7 0 9 0 6 0 ...

Page 2: ...ON WI FI SET UP MAINTENANCE SPECIAL MAINTENANCE AND REPLACING GROUP ROTOR CHECK LIST BEFORE USING CONTRALL APP KEY FEATURES LOSS OF WI FI CONNECTION AND CONTROLLER RESET CONTROLL APP AND ALERTS SYSTEM CONTRALL APP INFOS VOICE COMMANDS ONLINE HELP INSTRUCTIONS FOR THE CORRECT DISCHARGE OF THE PRODUCT ACCORDING TO EU DIRECTIVE 2002 96 EC WARRANTY DEEP Cleaning TIPS FOR A LONGER LASTING ...

Page 3: ...se of the controller included Furthermore by using your domestic Wi Fi network you can download the new SICCE App CONTRALL and manage the pump with your smarthphone Android system or iOS The SYNCRA SDC pumps offer a guarantee of a complete and efficient managment without limits of time and space Directly from your smartphone wherever you are you can control and monitor your system in a simple and ...

Page 4: ...dropped or damaged in any way 6 The pump must not work without water to avoid damages to the motor 7 The pump can be used in liquids or in environment with a temperature not higher than 35 C 95 F 8 Do not use the pump for uses different to those for which it has been projected as i e in bathroom or similar Applications 9 Avoid using the pump with corrosive and abrasive liquids 10 This pump require...

Page 5: ...light 11 Connector cable T TECHNICAL DATA 6 0 24 V 7 0 24 V 9 0 24 V Switching power supply INPUT 100 240V 50 60Hz OUTPUT 24V DC Q min max 2000 5500 l h 3000 7000 l h 4000 9000 l h 530 1450 US gph 800 1900 US gph 1000 2500 US gph H min max 1 0 3 5 m 2 0 5 0 m 2 6 7 0 m 3 5 11 5 ft 6 5 16 5 ft 8 5 23 0 ft Watt min max 10 40 W 20 65 W 30 95 W Cable length 3 0 m 10 0 ft 1 2 3 4 5 6 7 8 8 External dia...

Page 6: ...C SVE0055 SVE0053 Prechamber with closing ring D SPL0097 SPL0095 Anti vibration silicon feet E SVE0033 4 pcs Hose fittings for rigid and flexible pipes F STR0029 Protective grid G SPL0094 Controller H SKT0207 AC DC power adaptor EU I SKT0216 SKT0208 AC DC power adaptor US J SKT0217 SKT0209 AC DC power adaptor UK K SKT0218 SKT0210 AC DC power adaptor AU L SKT0219 SKT0211 B1 B C E D G F F H I J K L ...

Page 7: ...cord to the transformer and then to the power outlet The transformer is universal and works with all voltages and frequencies The pump is now powered but not active The controller must be positioned away from spray and moisture and where it can not accidentally fall into the water The Controller can be attached to the wall or aquarium cabinet using the included bioadhesive or screws Connect the fi...

Page 8: ...nd the risk of the pump to run dry The risk of invisible air bubbles creating a vacuum area is very high Damages which are caused by the pump running dry are excluded from warranty To maximize the pump s efficiency choose a straight inlet tube without elbows Pic 3 We suggest an Inlet and outlet tubes with diameter equal or bigger than the diameter of the threaded pipe included Pic 4 Do not use the...

Page 9: ... the pump s volute pulling the tab outwards Pic 6 2 Remove the ring Pic 7 3 Remove the volute of the pump by turning and simultaneously pulling forward in the case of fouling this may take more pressure 4 Pull out the complete rotor set Pic 8 5 Rinse each part with water using a soft brush to remove the deposit 6 Then assemble everything in the inverse order 6 7 8 O RING 2 O RING 1 MAINTENANCE ...

Page 10: ...automatically and remain in standby The controller will remain powered but the engine will shut down In this case to restart the pump you need to disconnect the plug for about 30 seconds and re insert it into the power socket Dry running protection motor s protection in case of functioning without water The pump stops when it works without water or if there is a locked rotor When the pump is taken...

Page 11: ...r limestone Insert the hook accessory inside the tube of the pump Pic 10 Hook the bearing and pull it out Clean the bearing under running water never use soap or detergent of any kind because they pollute the aquarium water we recommend using a vinegar and water solution possibly using a soft brush to remove scale deposits If it is heavily worn we suggest to replaces it with a new one Re insert th...

Page 12: ...the intensity of the Wi Fi signal The Wi Fi connection may not occur or be interrupted due to the environment of the home network The network connection may not work properly depending on the Internet service provider The surrounding wireless environment may slow down the wireless network service The device cannot be registered due to problems with wireless signal transmission Disconnect the devic...

Page 13: ...keys and it is possible to increase or decrease the pump flow Consequently the luminous intensity of the 5 LEDs will vary The pump symbol will light up in the color set via the CONTRALL App The Wi Fi symbol will flash blue slowly while waiting to be connected to the Wi Fi network via the CONTRALL App If the pump is managed via CONTRALL it will not be possible to modify its operation using the cont...

Page 14: ...tab on Choose these SYNCRA SDC Read the text and then Confirm PROCEED Next select the WIFI network you wish to link the pump and the WIFI psw Give a name to your pump and confirm with DONE It may take few seconds before the connection is active Faster Set Up with New configuration system WI FI SET UP ...

Page 15: ...and the user will receive a notification via email if this warning has been activated in the App CONTRALL The connection will be restored automatically as soon as the wireless network is available again WIFI AND CONTROLLER RESET Remove power from the controller Press and hold down the and buttons at the same time and re power the controller Keep them pressed until the Wi FiI LED flashes quickly Re...

Page 16: ...ART SYSTEMS it is possible to group together a series of individual devices for example 2 XSTREAM SDC pumps a SYNCRA SDC pump and a pump for skimmer PSK SDC and create a system to which to assign a distinctive name In case you want to manage multiple aquariums this function allows you to control them more immediately and efficiently It will be possible to switch off and switch on all devices by pr...

Page 17: ...ely safe solution to remove these deposits and keep your filter in tip top shape DEEP CLEANING TIPS FOR LONGER LASTING USE SICCE PUMP CLEAN TIPS In case after a first installation the pump will not be used for over one week we recommend to take the rotor assembly out of the pump cleaning it thoroughly and store pump and rotor separately The limestone deposits and the natural wear out of the compon...

Page 18: ...other waste It can be delivered to the specific electric waste collection centers or to dealers who give this service Discharge separately an electric tool avoid negative consequences for the environment and for the Health and allows to regenerate the materials so to have a great saving of energy and resources ONLINE HELP INSTRUCTIONS FOR THE CORRECT DISCHARGE OF THE PRODUCT ACCORDING TO EU DIRECT...

Page 19: ...e law The claimant must obtain a Return Merchandise Authorization at the time of filing before sending any product for warranty or technical service The purchaser bears the cost of shipping to and from the service center or repair station EXCLUSIONS This warranty does not cover the following Damage resulting from accident misuse abuse lack of reasonable care use of the product that is other than n...

Page 20: ...INSTRUCTION MANUAL EN SYNCRA SDC 6 0 7 0 9 0 INDEX SEAL AND SIGNATURE OF RESALE DEALER DATE OF PURCHASE ____ ____ ____ day month year WARRANTY ...