Page: 5 of 6
If the pump is subjected to temperatures of 32
°
F
[0
°
C]
or lower, the system must be drained of all liquid
to prevent damage due to freezing. It is suggested that when taking a pump out of service, the pump
and lines, etc. must be sanitized and purged of all fluid. Operating the pump at low pressure, simply
allow air to enter through the bag connector after the sanitizing procedure has been performed.
Opening the outlet valve will help in purging the lines of sanitizing solution. Refer to SHURflo Service
Bulletin
#
1025 for complete winterizing procedure.
CAUTION:
Purge with a maximum of 20 psi.
[1.4 bar]
, for approximately 3-5 seconds. The product outlet
fitting at the pump may also need to be removed and purged of any remaining solution.
Refer to the equipment manufacturer's recommendation on purging lines and dispenser
equipment. If there is any chance the solution may drain back to the pump leave the fitting
out of the port.
RETURN POLICY
Whenever a Juice pump is removed from service, it
MUST
be sanitized / flushed to prevent
contamination and possible health hazards.
Pumps that have not received periodic sanitization will
be deemed as non-returnable. For pumps that do not operate, warm water from a faucet can/
must
be
flushed through the inlet port as soon as it is removed from service. All Pumps returned to SHURflo that
have not been properly sanitized and/or flushed will be dispositioned as a "scrapped pump" and will not
be considered for testing, repair, or warranty replacement.
JUICE GAS PUMP LIMITED WARRANTY
SHURflo warrants Juice Gas Pumps to be free from material and workmanship defects (under normal
use and service) for a period of three (3) year from the date of manufacture.
The limited warranty will not apply to pumps that were improperly installed, misapplied, or not suitable with
components of other manufactures. The limited warranty will not apply to pumps subjected to fluids that
are incompatible with pump materials, or pumps operated by a contaminated air supply. SHURflo will not
warrant any pump that is physically damaged or modified outside the SHURflo factory.
All Juice pumps
MUST
be flushed of juice concentrate when removed from service. Pumps which are
returned to SHURflo which have not been flushed will not be considered for testing, rework, or warranty
replacement and will be dispositioned as a "scrapped pump".
All SHURflo gas pumps are to be returned to the authorized distributor where they were purchased.
SHURflo's obligation under this warranty policy is limited to the repair or replacement. Pumps found not
defective (under the terms of this limited warranty) are subject to charges to be paid by the returnee for the
testing and packaging of "tested good" units.
No credit or labor allowances will be given to the returnee for pumps returned as defective. Warranty
replacements will be shipped on a freight allowed basis. SHURflo reserves the right to choose the
method of transportation.
This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized
to give any other warranty or assume obligation or liability on SHURflo's behalf. SHURflo shall not be liable
for any labor, damage or other expense, nor shall SHURflo be liable for any indirect, incidental or
consequential damages of any kind incurred by the reason of the use or sale of any defective product or part.
This limited warranty covers beverage products distributed within the United States of America. Other world
market areas should consult with the distributor for any deviation from this document.