Page: 2 of 6
MAXIMUM HORIZONTAL DISTANCE by VISCOSITY (cP)
THE FOLLOWING TABLES ARE TO BE USED AS A GUIDELINE ONLY
*20-50 (cP)
FLOW RATE
1
/
4" [6mm]
I.D. TUBING
3
/
8" [10mm] I.D. TUBING
50% Apple 5:1
.0Z /SEC.
CC /SEC.
FEET
METER
FEET
METER
100% Apple 4:1
.25
7.4
272
83
500
152
Fruit Punch 5:1
.5
14.8
150
42
450
137
Lemonade 5:1
.75
22.2
101
31
303
92
Pink Lemonade 5:1
1.0
29.6
50
15
153
47
Lemon lime Soda 5:1
1.25
37.0
- -
- -
110
34
Typ. Heavy Soda Bev. 5:1
1.5
44.4
- -
- -
62
19
* For further viscosity charts in this range refer to Standard Gas Pump Manual # 911-293
50-100 (cP)
FLOW RATE
3
/
8" [10mm]
I.D. TUBING
1
/
2" [13mm] I.D. TUBING
50% Grape 5:1
.0Z /SEC.
CC /SEC.
FEET
METER
FEET
METER
100% Grape 5:1
.25
7.4
296
90
394
120
Grapefruit 5:1
.5
14.8
248
76
347
106
Cranberry 5:1
.75
22.2
205
63
298
91
Pineapple 5:1
1.0
29.6
150
47
251
77
1.25
37.0
78
24
206
63
1.5
44.4
54
16
153
47
1.75
51.8
- -
- -
112
34
2.0
59.2
- -
- -
59
18
100-500 (cP)
FLOW RATE
3
/
8" [10mm]
I.D. TUBING
1
/
2" [13mm] I.D. TUBING
50% O.J. 5:1
.0Z /SEC.
CC /SEC.
FEET
METER
FEET
METER
100% O.J. 4:1
.25
7.4
122
37
246
75
100% O.J. 3.5:1
.5
14.8
104
32
198
60
Margarita 4:1
.75
22.2
77
23
153
47
Tomato 1.5:1
1.0
29.6
56
17
105
32
1.25
37.0
29
9
50
15
1.5
44.4
13
4
27
8
500-1000 (cP)
FLOW RATE
3
/
8" [10mm]
I.D. TUBING
1
/
2" [13mm] I.D. TUBING
O.J. (Natural) 3:1
.0Z /SEC.
CC /SEC.
FEET
METER
FEET
METER
Tomato 2:1
.25
7.4
56
17
123
37
Bloody Mary 2:1
.5
14.8
32
9.7
100
30
Canadian Caesar 2:1
.75
22.2
17
5.2
78
24
1.0
29.6
7
2
52
16
1.25
37.0
- -
- -
27
8
1000-3500 (cP)
FLOW RATE
3
/
8" [10mm]
I.D. TUBING
1
/
2" [13mm] I.D. TUBING
O.J. (Natural) 5:1
.0Z /SEC.
CC /SEC.
FEET
METER
FEET
METER
Caesar 2:1
.25
7.4
49
15
96
29
.5
14.8
27
8
58
18
.75
22.2
13
4
32
10
1.0
29.6
- -
- -
18
6
•
Values in
Bold
create an inlet vacuum of 16" Hg. or higher at flow rates shown. Inlet tubing used was
3
/
8
" I.D.
[10mm] with a total length of 5 ft, with 3 ft. of vertical lift. Conditions of this kind should use
1
/
2
" [13mm] I.D.
vacuum tubing with minimal vertical lift. Fittings such as Liquibox Q.C.D.™ III connector and bag fittment are
less restrictive and utilize a larger barb fitting/tubing which can minimize inlet vacuum.
•
Product viscosity and solids content will vary, depending upon the manufacture and type of concentrate.
•
The tables above are the results of test conducted with 70 psi. [4.8 bar] (to the pump), with a minimum of 20 psi.
[1.4 bar] at the dispenser valve (to maintain brix). Ambient temperature was 70°F [20°C].