Charge

Displays charge as a percentage of the total battery capacity. Also shows time remaining to full charge.

Health

Displays health of selected battery as a percentage of the charge capacity of a new battery. Charge capacity (battery life 

when fully charged) will decline as a result of repeated charge cycles, age, or storage conditions.

Cycle

Displays total number of times that the battery has undergone one full count of discharge and charge. Recharging after dis­

charging halfway counts as one half of a cycle. Recharging after discharging a quarter of the way counts as one quarter of 

a cycle.

Temperature

Displays battery temperature (in Celsius and Fahrenheit) and status.

Charger Network Settings

To adjust charger network settings, open the charger properties panel in Wireless Workbench. Click the gear icon to set the IP 

mode and IP address, view the MAC address, and view firmware version.

Connecting to an External Control System

The SBC840 networked charging station connects to external control systems such as AMX or Crestron via the Ethernet. For a 

comprehensive list of command strings, 

visit the product page at https://www.shure.com

.

Connection: Ethernet (TCP/IP; SBC840 is the client)

Port: 2202

Specifications

SBC840

Battery Type

Up to 8 SB910/SB920

Charge Current

1.25 A maximum

Summary of Contents for SBC840

Page 1: ...SBC840 8 Bay Networked Charger Complete user guide for the SBC840 8 bay networked charger which fits SB910 and SB920 batteries Version 2 2 2021 E...

Page 2: ...ories 5 Controls and Connectors 5 Power 6 Power Save Mode 7 Charging 7 Storage Mode 8 Restoring Factory Settings 9 Connecting Shure Devices to Wireless Workbench 9 Configuration Tips 9 Monitoring Batt...

Page 3: ...USE attachments accessories specified by the manufacturer USE only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution w...

Page 4: ...other than Shure rechargeable batteries Dispose of battery packs properly Check with local vendor for proper disposal of used battery packs Batteries battery pack or batteries installed shall not be...

Page 5: ...icate charge status and errors Storage mode to prepare batteries for long term storage Network enabled for remote monitoring Furnished Accessories Power supply PS60 Note Model availability depends on...

Page 6: ...attery Ethernet Port Connect to a network to remotely monitor batteries and control charger settings using Wireless Workbench Ethernet Link Speed LED Amber Off 10 Mbps On 100 Mbps Ethernet Status LED...

Page 7: ...When the charge status and error LEDs flash amber release the button The charger remains in power save mode until you power off the charger Note Transmitters docked with the power switch in the ON po...

Page 8: ...Batteries are ready for storage Power LED red Charge status LED red flashing Batteries are approaching storage voltage Power LED white flashing Charger firmware is being updated All LEDs flashing Hard...

Page 9: ...y icon on the front panel location varies For most applications use the Automatic mode default to let your switch or router assign an IP address using DHCP addressing If no DHCP server is present your...

Page 10: ...discharging a quarter of the way counts as one quarter of a cycle Temperature Displays battery temperature in Celsius and Fahrenheit and status Charger Network Settings To adjust charger network setti...

Page 11: ...ability DHCP or Manual IP address Certifications Meets essential requirements of all applicable European Directives Eligible for CE marking The CE Declaration of Conformity can be obtained from www sh...

Page 12: ...nable protection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the i...

Page 13: ...Shure Incorporated 13 13...

Reviews: