background image

Shure Incorporated

11/12

Specifications

SBC450/SBC850

ULXD6 and ULXD8 Charge Time

15 minutes = 1 hour runtime; 1 hour = 50% charged; 3 hours = 100% charged

Network Interface

10/100 Mbps Ethernet

Power Requirement

15 V DC @ 4.0 A

maximum, supplied by external power supply (tip positive)

Housing

Molded Plastic, Cast Zinc Alloy

Dimensions

SBC450

82.1 mm x 224.4 mm x 192 mm ( 3.23 in. x 8.83 in. x 7.56 in.), H x W x D

SBC850

82.1 mm x 392 mm x 192 mm ( 3.23 in. x 15.43 in. x 7.56 in.), H x W x D

Weight

SBC450

1.59 kg ( 3.51 lbs)

SBC850

2.67 kg ( 5.89 lbs)

Operating Temperature Range

0°C (32°F) to 45°C (113°F)

Storage Temperature Range

-29°C (-20°F) to 74°C (165°F)

Certifications

Authorized under the verification provision of FCC Part 15B.

Industry Canada ICES-003 Compliance Label: 

CAN ICES-3 (B)/NMB-3(B)

Note: 

See the label located on the bottom side of the charger enclosure for the FCC marking, the CE marking, the RCM marking, the KC marking, and the 

electrical ratings.

Meets requirements of the following standards:

EN55032

EN55103-2

EN60065

Korea KN32/35

IEC60065

Summary of Contents for SBC450

Page 1: ...SBC450 SBC850 4 and 8 Bay Networked Docking Stations Complete user guide for SBC450 and SBC850 networked docking stations Version 3 2 2021 E...

Page 2: ...Connections 6 Connecting Transmitters 6 Connecting Shure Devices to Wireless Workbench 7 Configuration Tips 7 Monitoring Batteries with Wireless Workbench 7 Controlling Transmitters with Networked Do...

Page 3: ...aratus ONLY USE attachments accessories specified by the manufacturer USE only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used us...

Page 4: ...transmitters with Shure rechargeable batteries Connect to a network to adjust transmitter settings and monitor rechargeable batteries using Shure Wireless Workbench or SystemOn software or through a...

Page 5: ...er reset Place transmitters in docks Press and hold reset button for 5 seconds to restore transmitter factory set tings Transmitter mute LEDs flashing Power LED On Docking station is on Off Docking st...

Page 6: ...D Green Off No network link On Network link established Flashing Network link active Power Connections Connect power supply to a power outlet and to the docking station power input The docking station...

Page 7: ...twork connectivity Verify that Shure devices can see each other by looking for the network connectivity icon on the front panel location varies For most applications use the Automatic mode default to...

Page 8: ...w battery Charge capacity battery life when fully charged will decline as a result of repeated charge cycles age or storage conditions Cycle Displays total number of times that the battery has undergo...

Page 9: ...cking station Check that the docking station is connected to the network and to Wireless Workbench Find the docking station in the inventory and right click to select Properties Select one or multiple...

Page 10: ...smitters on the docking station and check that docking station is connected to the network Launch Shure Update Utility to find firmware updates Download updates and click Send Updates Model Variations...

Page 11: ...x 392 mm x 192 mm 3 23 in x 15 43 in x 7 56 in H x W x D Weight SBC450 1 59 kg 3 51 lbs SBC850 2 67 kg 5 89 lbs Operating Temperature Range 0 C 32 F to 45 C 113 F Storage Temperature Range 29 C 20 F t...

Page 12: ...thority for possible requirements Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment Licensing of Shure wireless microphone equipm...

Reviews: