background image

Shure Incorporated

4/14

Caution: risk of danger (See note.)

Direct current

Alternating current

On (Supply)

Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION

Stand-by

Equipment should not be disposed of in the normal waste stream

WARNING: 

Voltages in this equipment are hazardous to life. No user­serviceable parts inside. Refer all servicing to qualified service personnel. The safety cer­

tifications do not apply when the operating voltage is changed from the factory setting.

WARNING

Battery packs may explode or release toxic materials. Risk of fire or burns. Do not open, crush, modify, disassemble, heat 

above 140°F (60°C), or incinerate.

Follow instructions from manufacturer

Only use Shure charger to recharge Shure rechargeable batteries

WARNING: Danger of explosion if battery incorrectly replaced. Replace only with same or equivalent type.

Never put batteries in mouth. If swallowed, contact your physician or local poison control center

Do not short circuit; may cause burns or catch fire

Do not charge or use battery packs other than Shure rechargeable batteries

Dispose of battery packs properly. Check with local vendor for proper disposal of used battery packs.

Batteries (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like

Caution:

 Do not transport chargers with batteries inserted.

Warning: 

Do not charge batteries in enclosed spaces without proper ventilation.

Please follow your regional recycling scheme for batteries, packaging, and electronic waste.

Note: 

Model information and power ratings are labeled on the bottom of the unit.

General Description

The SBC240 networked docking charger provides a compact charging and storage solution for any combination of 2 SB910/

SB920 batteries or ADX1, ADX2, or ADX2FD transmitters using Shure rechargeable batteries. The charger is network-enabled 

to allow for remote monitoring of charger and battery parameters using Shure Wireless Workbench  software. Connect up to 4 

SBC240 chargers together to share power and network connectivity.

Features

Charging for any combination of up to 2 SB910/SB920 batteries or ADX1, ADX2, or ADX2FD transmitters using Shure 

rechargeable batteries

Connect up to 4 chargers together to share power and network connections and save space

®

Summary of Contents for SBC240

Page 1: ...SBC240 2 Bay Networked Charger Complete user guide for the SBC240 2 bay networked charger which can charge ADX1 ADX2 and ADX2FD transmitters or SB910 and SB920 batteries Version 2 1 2020 K ...

Page 2: ...Connectors 5 Power 6 Power Save Mode 6 Adding a Charger 7 Charging 8 Storage Mode 9 Restoring Factory Settings 10 Connecting Shure Devices to Wireless Workbench 10 Configuration Tips 10 Monitoring Batteries with Wireless Workbench 10 Charger Network Settings 11 Connecting to an External Control System 11 Vertical Mounting 11 Specifications 12 Certifications 13 Information to the user 14 ...

Page 3: ...Y USE attachments accessories specified by the manufacturer USE only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over UNPLUG this apparatus during lightning storms or when unused for long periods of time REFER all servicing to qualified service ...

Page 4: ...s other than Shure rechargeable batteries Dispose of battery packs properly Check with local vendor for proper disposal of used battery packs Batteries battery pack or batteries installed shall not be exposed to excessive heat such as sunshine fire or the like Caution Do not transport chargers with batteries inserted Warning Do not charge batteries in enclosed spaces without proper ventilation Ple...

Page 5: ...Screw 30B28875 Note Model availability depends on region See your local Shure dealer or distributor for details Controls and Connectors Power LED White Power is on Red Charger is in storage mode Reset Button Press and hold to restore charger factory settings including network settings Storage Mode Button Press and hold to activate storage mode which charges or discharges batteries to the optimal v...

Page 6: ...n Off No network link On Network link established Flashing Network link active Power Input Connect to power supply Charger Connector Use supplied screws and Allen wrench to connect up to 4 chargers to 1 power supply Power Connect DC power cable to input jack Finger tighten lock nut for a secure connection Connect power supply to AC power outlet WARNING Do not use pliers or any other tools to tight...

Page 7: ...harged To avoid unwanted audio and unnecessary battery drain ensure all transmitters are switched OFF before charging Adding a Charger To save space and reduce clutter up to 4 chargers can share 1 power supply and Ethernet connection Unplug charger from the power source Insert screws into the charger connector Align units and tighten screws using the supplied Allen wrench until they fit together s...

Page 8: ...eries and transmitters into the charging bays as shown The LEDs illuminate to indicate battery status Warning Do not insert transmitters using AA batteries LED Indicators Color State Charge status LED red Charging Charge status LED green Charging complete ...

Page 9: ...te but battery temperature is too warm or cold over 60 C or below 0 C Power LED red Charger is in storage mode Batteries are charging or discharging to stor age voltage Power LED red Charge status LED amber Batteries are ready for storage Power LED red Charge status LED red flashing Batteries are approaching storage voltage Power LED white flashing Charger firmware is being updated All LEDs flashi...

Page 10: ...et cable to ensure reliable network perfor mance If you have multiple devices to manage connect each device to a router or network switch The Ethernet port LEDs on your device will illuminate to indicate network connectivity Verify that Shure devices can see each other by looking for the network connectivity icon on the front panel location varies For most applications use the Automatic mode defau...

Page 11: ...ischarge and charge Recharging after dis charging halfway counts as one half of a cycle Recharging after discharging a quarter of the way counts as one quarter of a cycle Temperature Displays battery temperature in Celsius and Fahrenheit and status Charger Network Settings To adjust charger network settings open the charger properties panel in Wireless Workbench Click the gear icon to set the IP m...

Page 12: ...cations SBC240 Compatible Batteries Up to 2 SB910 or SB920 Compatible Transmitters Up to 2 ADX1 ADX2 or ADX2FD Charge Current 1 25 A maximum Charge Time 1 hour 50 charged 3 hours 100 charged External Power Supply PS60 Power Requirement 15 V 3 33 A maximum Housing Molded Plastic Dimensions 65 25 x 88 74 x 210 82 mm 2 57 x 3 49 x 8 30 in H x W x D ...

Page 13: ...er Str 12 75031 Eppingen Germany Phone 49 7262 92 49 0 Fax 49 7262 92 49 11 4 Email info shure de Operation of this device is subject to the following two conditions 1 this device may not cause interference and 2 this de vice must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables a...

Page 14: ...eception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Reviews: