background image

NOTES TO THE CIRCUIT DIAGRAM

D.C. Voltage Measurements:

Check the DC voltages before checking AC voltages be-

cause transistors Q2 through Q9 are direct coupled and
any deviation from the nominal voltages will affect the AC

voltages. The four key DC voltages are +94, +20, the

emitter of Q1, and the split voltage at the junction of R3,

R5, R7, and R8. If these four key DC voltages are correct,
then proceed with the AC voltage measurements.

The numbers within the symbol

on the circuit dia-

gram 

denote the DC voltage at that point with the follow-

ing test condition:
1. Voltages measured at points indicated with respect to

chassis, unless otherwise specified.

2.

Line voltage PM300: 120 V. 60 Hz.; PM300E: 120/240 V.

50/60 Hz.; PM300E6: 100, 120, 140, 200, 220, or 240 V.
50/60 Hz.

3. No input signal applied.
4. DC voltage measurements may vary ±20% from the

values shown.

5. Measured with a VTVM of 11-megohms input imped-

ance.

A.C. Voltage Measurements:

The numbers within the symbols

on the circuit

diagram denote the AC voltage at that point with the fol-

lowing test conditions:
1. Voltages measured at points indicated with respect to

chassis, unless otherwise specified.

2. Line voltage as specified above.
3. 1,000 Hz. signal applied to one of the high impedance

parallel inputs at 300 millivolts (.3 volts).

4.

Measured with an AC VTVM of 1.0 megohms or greater
input impedance.

5. Noninductive load of 8 ohms, 200 watts connected to

speaker output jack.

6. Volume control set to maximum.
7. AC voltage measurements may vary ±20% from the

values shown.
Shure part numbers are not shown in the Parts List, ac-

companying the circuit diagram, if parts are readily avail-
able through local electronic parts supply distributors. In
these instances, the circuit diagram will show the values of
the standard parts.

All capacitor values are shown in microfarads. All non-

electrolytic capacitors are to be 100 volts or more unless
otherwise specified in the circuit diagram. Electrolytic
capacitors are shown in microfarads and volts.

All resistor values are shown in ohms. Resistors are all

to be 10% tolerance unless specifically noted on the cir-
cuit diagram.

All resistors are ½ watt unless otherwise specified.
The following ground symbol

denotes chassis ground:

Ohmmeter Measurements:

With the A.C. line cord unplugged and the power switch

in the “OFF” position, the following ohmmeter measure-
ments may be made.
1. B+ to ground approximately 100 ohms.
2. Ohmmeter plus probe to the junction of R3, R5, R7, and

R8, ohmmeter minus probe to ground; greater than 120
ohms.

3. Ohmmeter plus probe to B+, ohmmeter minus probe to

the junction of R3, R5, R7, and R8: greater than 120
ohms.

4. To test transistors and diodes, see page 7.

PM300 

CIRCUIT DIAGRAM

NOTES:

1. ALL CAPACITORS IN MFD AND 100 VOLTS OR MORE

UNLESS SHOWN. ELECTROLYTIC CAPACITORS SHOWN
IN MFD x VOLTS.

2. ALL RESISTORS 10%, ½ WATT, UNLESS OTHERWISE

INDICATED. R3 THRU R8 10%, 5 WATT.

3. THE FOLLOWING SYMBOLS DENOTE:

DC VOLTAGE

AC VOLTAGE

WITH RESPECT TO CHASSIS UNLESS OTHERWISE
SHOWN.

4. R

SEL

 MAY BE 180 OR 82 OHMS, OR NOT USED, DEPENDING

ON POWER 

DRAIN 

(SEE PAGE 7).

FIGURE 7.

9

Summary of Contents for PM300 SERIES

Page 1: ...PM300 SERIES OPERATING AND SERVICE MANUAL Manufactured by SHURE BROTHERS INC 222 Hartrey Avenue Evanston Illinois 60204 U S A Copyright 1978 Shure Brothers Inc AL 407 RE 27A822 Printed in U S A...

Page 2: ......

Page 3: ...m and Noise 80 db below rated output Speaker Load Impedance Nominal 8 ohms Operational 5 3 ohms minimum see Page 4 Dimensions 178 mm height x 429 mm width x 229 mm depth 7 in x 16 7 8 in x 9 in Weight...

Page 4: ...FIGURE 1 FIGURE 2 2...

Page 5: ...Power Master to the jack marked To Tape Recorder on the VA300 C or to the jack marked Aux Hi Level Output on the VA302 Series Console con nect the other end of the cable to one of the jacks marked Hi...

Page 6: ...as a monitor at the high est possible sound level without feedback The following list shows various speaker combinations and the resultant impedance loads which are suitable for use with the Power Mas...

Page 7: ...d in an ambient temperature range from 7 C to 43 C 20 F to 110 F for continuous duty without de rating Thermal Overload The Power Master is equipped with thermal sensing switches on the heat sinks of...

Page 8: ...ement and before connecting transistor leads check transistors with an ohm meter between case and chassis there should be no con tinuity Be sure that these transistors are not inverted in the circuit...

Page 9: ...the ohmmeter plus probe on the anode end of a diode and the minus probe on the cathode end the ohmmeter should read approximately 2 000 ohms or less With the meter probes reversed a reading of about 1...

Page 10: ...32A627 None 90BC2600 65A685 90B2285 95A500 95A604 Knob and Screw Line Cord Storage Spindle Handle and Nuts Bumper Plastic Foot Volume Control Knob Assembly Fuse Holder PM300 and PM300E Fuse Holder 5x2...

Page 11: ...me control set to maximum 7 AC voltage measurements may vary 20 from the values shown Shure part numbers are not shown in the Parts List ac companying the circuit diagram if parts are readily avail ab...

Page 12: ...PM300E POWER SUPPLY CIRCUIT DIAGRAM FIGURE 8 PM300E6 POWER SUPPLY CIRCUIT DIAGRAM FIGURE 9 10...

Reviews: