1.
2.
•
•
Resetting Devices
Shure devices are designed to work together right out of the box. Prior to a new installation, or during troubleshooting, it may
be useful to reset devices to ensure system compatibility.
The system provides 2 reset levels to choose from:
Network reset:
Clears only network settings and provides a fresh network connection.
System reset:
Clears all device and system settings to reset the device to default factory settings.
From the Hardware
Access Point
Press and hold the recessed reset button.
Network reset:
Press and hold for 5 seconds to reset any network settings and refresh
network connection.
System reset:
Press and hold for 10 seconds to reset the device to default factory set
tings.
See
Access Point Transceiver (MXCWAPT)
for more details on LED behaviors during a
reset.
Conference Units
Access the technician menu by tapping the
gear icon. While at the top of the set
tings page, hold down the volume control knobs and tap the right side of the screen.
Go to the
information screen and tap
Factory reset
.
Networked Charging Sta
tion
Press and hold the recessed reset button.
Network reset:
Press and hold for 4 seconds to reset any network settings and refresh
network connection.
System reset:
Press and hold for 8 seconds to reset the device to default factory set
tings.
From the Software
Access Point
Go to
Settings
>
Device
reset
. Select
Reboot device
or
Restore facto
ry defaults
.
Conference Units
Go to
Devices
and select a device. From the device properties panel, open
more options and select