background image

3

result. Turn the Phantom switch off when phantom power
is not required.

Three-Socket XLR Input connector: provides for
connection to microphone or line level input signal
sources.

Input Mic/Line Slide Switch: selects microphone or
line-level input signals.

Link In, Out Phone Jacks: provide for connecting more
distribution amplifiers for additional outputs, or adding
external equipment such as equalizers, compressors, or
limiters. When connecting two or more FP16As together
for additional outputs, connect the Link Out jack of the
”master” unit to the Link In jacks of the others. Any
number of FP16As can be tied together in this way. The
Link In jack is input-only, and has switching contacts to
disconnect the input signal amplifier from the output
channel volume controls.
    Connect an equalizer, limiter or compressor to the
FP16A by connecting the FP16A Link Out jack to the
external unit’s input, and the external unit’s output to the
FP16A Link In jack.
    Signals at the Link jacks are typically 10 dB below line
level. The Link In input impedance is greater than 20 k

and may be considered a bridging impedance.

INSTALLATION AND OPERATION
Battery Operation

In addition to 120 or 240 VAC operation, the FP16A can
be operated from an internal battery pack. Current drain
is typically 22 mA at +4 dBm output level. Battery
operation is recommended for remote, on-location
operation, and as an emergency backup source in case
of AC power failure.  
   Access to the battery compartment is through the
bottom of the chassis. Three 9 volt transistor radio
batteries power the FP16A at full rated output. Use
alkaline batteries for maximum life. Duracell MN1604 or
Eveready 522 are recommended. Battery life is
approximately 20 hours at +4 dBm continuous use. Note
that phantom power loading will increase battery drain.  
   With batteries in the battery compartment, the FP16A
will automatically and silently switch to battery operation
should the AC voltage fall below a suitable level.

Connections

Connect the signal source to the three-socket XLR Input
connector and set the input Mic/Line switch for the proper
level. Connect the three-pin XLR 1-6 Output connectors
to low-impedance microphone or line level inputs of
power amplifiers, mixers, etc. Set each Mic/Line switch
for the appropriate signal level.
   Connect additional distribution amplifiers or add
external equipment using the FP16A Link jacks (see
Controls and Connectors). A common ground connection
can be established using the rear-panel Ground binding
post.
   Connect the line cord to a 120 VAC 

±

10%, 50/60 Hz

source if the FP16A is to be ac-operated. If 240 volt AC
operation is desired, refer to the Service section.

Adjustments

Turn the On-Off switch to the On position (Power LED will
light). Turn the Phantom switch on if a
non-battery-operated condenser microphone is to be
used with the FP16A.
   With an input signal applied, adjust the Input gain
control so that the Norm LED flickers during normal
speech or music (the Overload LED will flicker as the
signal level approaches clipping). Adjust the Output 1-6
controls to provide an adequate signal feed to the
following equipment.

Telephone Interconnection

When using the FP16A connected directly to a telephone
line, check to see whether the telephone company
requires an interface coupler between the FP16A and the
telephone line. If a coupler is required, make certain the
coupler selected and the wiring arrangement are in
compliance with local telephone company regulations.
   When direct connection to a telephone line is not
possible, acoustic coupling to a telephone handset may
be used. A Shure Model 50AC Telephone Acoustic
Coupler can be connected to the 600 ohm line output of
the FP16A and attached to most telephone handsets.

Telephone Line Surge Protection

When using the FP16A connected directly to a telephone
line subject to lightning-induced voltage surges, the
following part (commercially available) can be installed
across the LINE OUT terminals to provide additional
protection for output circuit components: Metal Oxide
Varistor, General Electric Co., Type No. V22ZA1.

ACCESSORIES

The Model A16R Rack Panel Kit consists of a 19 in, x
3-1/2 in. (483 mm x 89 mm) precut rack panel and
necessary hardware for rackmounting the FP16A with its
cover in place and end caps removed in a standard 19”
(483 mm) rack panel.

SERVICE

Caution:  These servicing instructions are for use by
qualified personnel only. To avoid electric shock, do not
perform any servicing other than that contained in the
Operating Instructions unless you are qualified to do so.
Refer all servicing to qualified service personnel.

The FP16A can be disassembled as follows. Remove
two screws fastening each end cap. Remove four screws
securing the cover assembly to the chassis. Carefully lift
the cover assembly up and away from the chassis, taking
care not to snag any wire leads or components.

240 VAC Operation

To change the FP16A operating voltage from 120 VAC to
240 VAC, follow these steps.

Summary of Contents for FP16A

Page 1: ...is switchable to low impedance microphone or line level S Phantom power for condenser microphones available at input S Six isolated transformer coupled XLR outputs are switchable to low impedance balanced mi crophone or 600 ohm balanced line level S Link input and output jacks permit ganging of FP16s for additional outputs or adding external equipment such as equalizers compressors or limiters S R...

Page 2: ... VDC nominal 3 3k series resistance automatical ly disabled with input switch in Line position Operating Voltage AC Operation 120 or 240 VAC 10 internally se lectable 50 60 Hz 5 5W DC Operation 27 VDC nominal at 16 mA typical no signal 22 mA typical at 0 VU 4 dBm output 21 5 VDC minimum battery life approximately 20 hours with alkaline batteries at 4 dBm output in continuous use three 9 volt batte...

Page 3: ...k jacks see Controls and Connectors A common ground connection can be established using the rear panel Ground binding post Connect the line cord to a 120 VAC 10 50 60 Hz source if the FP16A is to be ac operated If 240 volt AC operation is desired refer to the Service section Adjustments Turn the On Off switch to the On position Power LED will light Turn the Phantom switch on if a non battery opera...

Page 4: ...re 86A415 TI GE 1N4148 D201 D204 D206 D207 Silicon Rectifier 100V 1 2A Shure 60201FT Motorola 1N4002 D205 Zener Diode 9V 112W Shure 60202FT Motorola1N5239 D601 Light Emitting Diode Green Shure 60204FT Rohm SLR34MG3 D701 Light Emitting Diode Yellow Shure 60205FT Rohm SLR34YY3 D702 Light Emitting Diode Red Shure 60206FT Rohm SLR340R3 F201 Fuse Slow Blow 3AG 100 mA 250V Shure 60207FT Littelfuse 313 0...

Page 5: ... et silencieuse S Construction robuste et durable S Léger et compact pour faciliter le transport et son utilisation sur le terrain S Fonctionnement fiable même lorsque les condi tions de température et d humidité sent extrêmes S Rackable en 19 pouces 2 unités avec acces soire optionnel A16R CARACTERISTIQUES TECHNIQUES Réponse en fréquence réf 1 kHz 30 Hz à 20 kHz 2 dB Gain de tension réf 1 kHz ENT...

Page 6: ... Ligne du FP16A est en position micro NE PAS mettre I interrupteur en marche lorsque I on utilise des microphones basse impédance non symétriques il en résulterait des ronflements indésirables Couper I alimentation fantôme lorsqu elle n est pas nécessaire Prise d entrée en XLR à trois cosses INPUT permet la connexion à des signaux sources en niveaux micro ou ligne Interrupteur MIC LINE sélectionne...

Page 7: ...urs à un couplage acoustique avec le combine téléphonique Le coupleur acoustique pour téléphone Shure modèle 50AC peut être connecté à la sortie ligne de 600 Ohms du FP16A et fixé à la plupart des combinés téléphoniques Protection contre les surcharges des lignes télépho niques Si le FP16A est directement connecté à une ligne téléphonique sujette à des surtensions dues à la foudre la pièce suivant...

Page 8: ...matisches Umschalten von Netzauf Batteriebetrieb und umgekehrt S Robuste dauerhafte Konstruktion S Kompakt und leicht ideal für aussenproduktio nen und Transport S Zuverlässiger Betrieb über einen weiten Temper atur und Luftfeuchtigkeitsbereich S Kann mit dem zusätzlichen Gestelleinbausatz in ein Gestell eingebaut werden TECHNISCHE DATEN Frequenzbereich bei 1 kHz 30 Hz 20 kHz 2 dB Spannungsverstär...

Page 9: ...er des FP16A in Mic Stellung ist Den Phantomschalter bei Verwendung von unsymmetrischen niederohmigen Mikrofonen nicht einschalten dies führt zu lästigen Brummstörungen Den Phantomschalter ausschalten wenn Phantom Speisung nicht erforderlich ist 3 poliger XLR Input Stecker zum Anschluss an Mikrofon oder Leitungspegel Eingangs Signalquellen Eingang Mic Line Schalter schaltet zwischen Mikrofon oder ...

Page 10: ...kustik Koppler 50 AC kann an den 600Ω Leitungsausgang des FP16A angeschlossen und mit den meisten Telefonapparaten verbunden werden Schutz vor Spannungsspitzen in der Telefonleitung Wird der FP16A direkt an eine Telefonleitung angeschlossen die Spannungsspitzen durch Blitzschlag ausgesetzt ist kann das folgende Teil im Handel erhaltlich zwischen den LINE OUT Klemmen zum zusätzlichen Schutz der Aus...

Page 11: ...11 Shure Model FP16A Distribution Amplifier ...

Page 12: ...ated Web Address http www shure com 222 Hartrey Avenue Evanston IL 60202 3696 U S A Phone 847 866 2200 Fax 847 866 2279 In Europe Phone 49 7131 72140 Fax 49 7131 721414 In Asia Phone 852 2893 4290 Fax 852 2893 4055 Elsewhere Phone 847 866 2200 Fax 847 866 2585 ...

Reviews: