background image

5

Device ID

The device ID identifies the transmitter on a 

network in WWB software or when linked to 

a receiver. 
•  ID length can be up to 8 characters 
•  Use arrow buttons to scroll through 

characters 

•  Use 

Set

 button to save and move to next 

character 

Frequency

Press the 

set

 button once to highlight the 

first 3 digits for editing, or twice to highlight 

all digits for editing. Use the arrow buttons 

to change each digit.
When finished, press the 

set

 button to save 

changes.

RF Mute

Disables the RF signal to mute the audio 

output. 

TX On:

 Audio output on 

TX Off:

 Audio output muted 

Gain

Adjust the gain to set audio output level. 
Gain range is -10 to +20 dB, in 1 dB steps. 

Sens

(sensitivity)

Adjust the sensitivity to compensate for input 

level variation.
Sensitivity settings are 0 or +12 dB

RF PWR

From the main menu screen, press and hold the 

▼ and 

set

 button to edit the RF power level. 

Use lower power settings to conserve battery life 

and to prevent RF overload at the receiver.

Note: 

A password is required in some regions. 

Firmware

Displays the firmware version installed in the 

transmitter 

Unlink

The unlink command ends the linking relation-

ship between a transmitter and a receiver. 

YES:

 Ends the link between a transmitter and a 

receiver. 

NO:

 Preserves the link between a transmitter 

and a receiver. 

Note: When a transmitter is unlinked, the chan-

nel name will revert to 

unlinked

PCB Serial Number

Use this menu to view the serial number of the 

printed circuit board (

PCB

) installed in the unit.

1. From the main menu screen, press and 

hold the ▼ and “set” buttons to enter the 

RF 

Power

 screen.

2. Press the▲ button to access the serial num-

ber .

3. Momentarily press the power button to return 

to the home menu screen.

AA Type

Sets the AA battery type to ensure accurate 

runtime display when using the optional battery 

sled. 

Alkaline
NiMH
Lithium

Showlink Test

Activates the ShowLink test 5-bar display to 

measure the control range of a ShowLink ac-

cess point. 
•  5 bars indicate the center of the coverage 

area 

•  1 bar indicates the outer boundary of the 

coverage area 

•  If bars are not displayed, ShowLink control is 

not available 

Troubleshooting 

Input Overload 

The 

Input Overload

 message indicates an excessive signal level at 

the transmitter input. To remove an overload, reduce the gain or sensi-

tivity settings. 

No ShowLink Alert

This alert is appears if you try to change the frequency when the trans-

mitter is beyond the range of an active ShowLink access point. Choose 

OK

 to unlink the transmitter and complete the frequency change, or 

Cancel

 to return to the home screen.

Group (G) and Channel (C)

A group is a set of pre-set frequencies. A single 

frequency within a group is a channel. 

G:

 Change the group 

C:

 Change the channel 

Firmware Updates 

Firmware is embedded software in each Axient component that controls functionality. Periodically, new versions of firmware are developed to in-

corporate additional features and enhancements. To take advantage of design improvements, new versions of the firmware can be uploaded and 

installed using the Firmware Update Manager tool available in WWB6 software. Firmware is available for download from . 

Parameter Menus 

To adjust transmitter settings, use the arrow buttons to access and edit the parameter menus.

Input

Overload

  

No ShowLink.

  UNLINK Tx to
  change freq?
  OK     Cancel

Draft 

6/7/11

Summary of Contents for AXT210

Page 1: ...AXT210 Handheld Single Channel Transmitter 2011 Shure Incorporated 27A15019 Rev 1 D r a f t 6 7 1 1...

Page 2: ...ases on the appara tus The MAINS plug or an appliance coupler shall remain readily oper 16 able The airborne noise of the Apparatus does not exceed 70dB A 17 Apparatus with CLASS I construction shall...

Page 3: ...t in use 1 1 Main Menu Screen The main menu screen displays the following transmitter parameters Link Status Linked Displays linked receiver ID Unlinked Not linked to a receiver Frequency Tuned freque...

Page 4: ...er is within range of a ShowLink access point Shure Li ion rechargeable battery delivers up to 10 hours of runtime from a single charge Rugged sleek industrial design that withstands the demands of ex...

Page 5: ...er the RF Power screen 2 Press the button to access the serial num ber 3 Momentarily press the power button to return to the home menu screen AA Type Sets the AA battery type to ensure accurate runtim...

Page 6: ...s low power mode Dimensions 261 mm x 37 mm 10 3 in x 2 6 in L x Dia Weight 395 g 13 9 oz with batteries Housing Machined aluminum Operating Temperature Range 18 C 0 F to 63 C 145 F Note Battery charac...

Page 7: ...ar Industrie Canada Dans le but de r duire les risques de brouillage radio lectrique l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrop...

Page 8: ...shure com hk United States Canada Latin America Caribbean Shure Incorporated 5800 West Touhy Avenue Niles IL 60714 4608 USA Phone 847 600 2000 Fax 847 600 1212 USA Fax 847 600 6446 Email info shure co...

Reviews: