Shure Incorporated
14/23
1.
2.
◦
◦
3.
•
•
1.
2.
3.
4.
From the Radio menu, navigate to Output.
Choose one of the following options:
On: RF signal is active
Mute: RF signal is disabled
Press O to save.
Turning the transmitter off and on, or replacing the battery will restore Output to On.
Safe Start
Power on in Safe Start mode to prevent interference with other devices. Hold the X button while powering on your device until
the Safe Start menu appears.
Safe Start menu options:
RF: Mute or On
Locks: None, Pwr, Menu, All
Use the navigation buttons to make changes.
To exit the Safe Start menu, cycle the power or momentarily remove the battery.
Previous settings for locks and RF will be retained when the transmitter is powered on in Safe Start.
Operating in Frequency Diversity Mode
Operating the AXDFD2 in frequency diversity mode with an Axient Digital receiver enables simultaneous transmission of audio
on 2 independent frequencies.
Select a channel and navigate to the Frequency Diversity setting:
Advanced
>
Frequency
Diversity
.
Use the control wheel to select the Combining option.
Press ENTER to confirm and save.
Perform an IR sync to link the transmitter to the receiver.
In Frequency Diversity, the transmitter will operate on two adjacent receiver channels (1 and 2 or 3 and 4).