background image

SHURE Incorporated  Web Address: http://www.shure.com
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
In U.S.A., Phone: 1-847-600-2000  Fax: 1-847-600-1212
In Europe, Phone: 49-7131-72140  Fax: 49-7131-721414
In Asia, Phone: 1-852-2893-4290  Fax: 1-852-2893-4055
International Fax: 1-847-600-6446

ENVIRONMENTAL QUALIFICATION FORM, TSO-C58a

DO-214

PARA. #

CONDITIONS

DO-160C

PARA. #

DESCRIPTION OF TESTS

2.5.1.1

Ground Survival Low Temperature
and Operating Low Temperature

4.5.1

Microphone tested to Category D1

2.5.1.2

Ground Survival High
Temperature and Short-Time
Operating High Temperature

4.5.2

Microphone tested to Category D1

2.5.1.3

Operating High Temperature

4.5.3

Microphone tested to Category D1

2.5.1.4

Altitude

4.6.1

Microphone tested at altitude equivalent to 15,200 m
(50,000 ft) = 11.6 kPa (116 mbar, 87 mm [3.42 in.] Hg)

2.5.1.5

Decompression

4.6.2

Microphone tested at altitude equivalent to 15,200 m
(50,000 ft)

2.5.1.6

Overpressure

4.6.3

Microphone tested at pressure = 170 kPa; equivalent
altitude = –15,000 ft

2.5.2

Temperature Variation –
Preamplifier

5.3

Microphone tested to Category B for two cycles.

2.5.3

Humidity

6.3.1

Microphone tested to Category A for 2 cycles.

2.5.5

Vibration

8.5

Microphone tested to Categories N, B, & M (Table 8-1,
Not on Vibration Isolators)**

2.5.6

Magnetic Effect

15.3

Microphone tested to Equipment Class Z; no
magnetic properties

2.5.8.1

Voltage Spike Conducted

17.3

Microphone tested to Category A

2.5.10

Induced Signal Susceptibility*

19.3

Microphone tested to Category Z

2.5.11

Radiated RF Susceptibility*†

20.5

Microphone tested to Category A

2.5.12

Emission of RF Energy*

21.4

Microphone tested to Category Z

2.5.14

Final  Distortion

After all  required environmental tests microphone
meets requirements of DO-214, 2.6.2.4

2.5.15

Push-To-Talk Switch Life

After all  required environmental tests microphone
meets requirements of DO-214, 2.6.2.9

Fire Retardance

In accordance with FAR 25; 25.869(a)(4) and
Appendix F, Part I (a)(3)(b)***

* Tests performed at Radiometrics Midwest Corporation, 

Lombard, IL

† 

Tested to DO-160B

**Tests performed at Elite Electronic Engineering, 

Downers Grove, IL

***Tests performed at Gaynes Test Laboratories, Chicago, IL
All other tests performed at Shure Incorporated, Evanston, IL