background image

IMPEDANCE SELECTION-

RECEPTACLE END OF MICROPHONE

FIGURE 4

INTERNAL CONNECTIONS

FIGURE 5

CONNECTIONS

When using the microphone in low impedance, the

cable conductors from connector pins 2 and 3 are the audio
signal carriers. Connect the shield to amplifier or chassis
ground.

When using the microphone in high impedance, the

cable conductor from pin 3 and the shield are the audio sig-

nal carriers. Connect the conductor from pin 3 to the “hot”
amplifier input; connect the shield to amplifier or chassis
ground. An unused lead attached to pin 2 should be insu-
lated before attaching a connector to a two-conductor

shielded bare-ended cable.

PHASING

To test two microphones and/or their cables for proper

phasing, connect them to an amplifier and talk or sing into

them while holding them three or four inches apart. The
sound from the speakers should be the same when talking

into either microphone or directly between them if they are
in phase with each other. If the sound drops drastically, or if
a dead spot is found when talking between the two micro-
phones, either the microphones or their cables (low imped-

ance only) are out of phase. All cables and microphones
should be tested in this manner to ensure that they are in
phase with each other.

To change the phase of a low-impedance microphone

cable, either use a Shure A15PRS Phase Reverser or inter-

change the wires connected to pins 2 and 3 of the connector.
To change the phase of a microphone, the microphone car-
tridge leads must be interchanged (see Figure 5). This
should be performed by your dealer, the Shure Factory Ser-
vice Department, or other qualified service personnel.

FURNISHED ACCESSORY

Swivel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A25E

OPTIONAL ACCESSORIES

Line Matching Transformer . . . . . . . . . . . . . . .  A95 Series
Desk Stand

. . . . . . . . . . . . . . . . . . . . . . . . . . . S37A, S39P

Isolation Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A55M
Dual Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A25M

Windscreen

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2WS

Cable, LO-Z (6.1 m - 20 ft)  . . . . . . . . . . . . . . . . . . . .  C20H
Cable, LO-Z (6.1 m - 20 ft, mic connector only) . . C20D
Cable, HI-Z (6.1 m-20 ft) . . . . . . . . . . . . . . . . . . . . .  C2OP

REPLACEMENT PARTS

545D-LC

545SD-LC 545SD-CN

Cartridge

R45

R45

R45

 . . . . . . . . . . . . . . 

C20H

Plug Element

RK169P

RK169P

RK169P

ARCHITECTS’ SPECIFICATIONS

The microphone shall be a moving coil (dynamic) type

with a frequency response of 50 to 15,000 Hz. The unit shall

have a cardioid polar characteristic. The cancellation at the

the rear shall be 15 to 20 dB. The microphone shall be dual

impedance with a rated impedance of 150 ohms for connec-

tion to microphone inputs rated at 19 to 300 ohms and “High”
for connection to high-impedance microphone inputs. Impe-
dance change shall be solderless at the microphone con-

nector.

The microphone output shall be:

Low Impedance . . . . . . . . . . . . . . . . . . . . . . . . . .

(0 dB = 1 milliwatt per 10 microbars)

High Impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . 

(0 dB = 1 volt per microbar)

audio connector.* Models 545SD-CN and 545SD-LC shall

The microphone shall be provided with a swivel adapter,

able for mounting on a stand having a 

5

/

8

”-27 thread.

The overall dimensions of the microphone shall be 157

mm (6-

3

/

16

 in.) in length and 31.9 mm (1-

1

/

4

 in.) in diameter.

The microphone shall be the Shure Model 545D-LC,

545SD-CN, 545SD-LC or equivalent.

*Designed to mate with Cannon XL series, Switchcraft

A3 (Q.G.) series or equivalent connector

The Sound of Professionals...Worldwide™

Shure Brothers Incorporated

222 Hartrey Avenue, Evanston IL 60202-3696

Reviews: