The microphone circuit of the 527A is normally closed

when the microphone switch button is in the normal position.

The microphone switch may be rewired to have a normally

open microphone circuit. To modify the 527A for a normally

open circuit, proceed as follows:
1. Remove the three No. 6 Phillips self-threading screws 

from the back of the microphone case.

2. Separate the case front and back, then remove the 

microphone switch button.

3. Unsolder or clip the WHITE cable lead and the RED 

transformer lead from the switch solder lug (see 
Figure 2).

4. Solder the WHITE cable lead and the RED transformer 

lead to the lower switch solder lug. 

5. Place the microphone switch button in the normal posi-

tion on the case front. Place the case back on the case 
front and firmly press the two sections together. Fasten 
the case back to the case front with the screws previ-
ously removed.

OPERATION

The 527A will operate satisfactorily under all ordinary con-

ditions of humidity, heat, and cold. Dropping the microphone

or other severe mechanical shocks should be avoided.

SPECIFICATIONS
Type

Dynamic

Frequency Response

200 to 5,000 Hz

Output Level 

(at 1,000 Hz)

-15 

±

4 dBV/100 

μ

bars

Impedance

 (at 1,000 Hz)

21 k

Ω

 minimum

Hum Sensitivity

30 

±

5 dB equivalent SPL per 1 mOe 

Switch

Double-pole, single-throw, leaf-type

Cable

Attached, 1.5 m (5 ft.), 3-conductor (1 shielded), 

coiled-retractable, neoprene-jacketed

Dimensions

OVERALL DIMENSIONS

FIGURE 3

Net Weight

292 g

Certification

Conforms to European Union directives, eligible to bear

CE marking; meets European Union EMC Immunity Re-

quirements (EN 50 082-1, 1992); RF radiated (IEC 801-3);

ESD (IEC 801-2); EFT (IEC 801-4).

FURNISHED ACCESSORY

Mounting Bracket (3 in kit). . . . . . . . . . . . . . . RK6MB

REPLACEMENT PARTS

Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R131
Switch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  RK319S
Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  C12C
Transformer . . . . . . . . . . . . . . . . . . . . . . . . . 90A4319

For additional service or parts information, please contact

Shure's Service department at 1-847-600-8699. Outside the

United States, please contact your authorized Shure Ser-

vice Center.

20

20000

1000

10000

50 100

9

8

7

6

5

4

3

2

9

8

7

6

5

4

3

2

+10

0

–10

Hz

dB

-20

+20

93.7 mm

(3-11/16 in)

66.7 mm

(2-5/8 in)

55.8 mm

(1-49/64 in)

9.5 mm (3/8 in)

19.1 mm (3/4 in)

0.8 mm (1/32 in)

1.6 mm (1/16 in)

2.4 mm (3/32 in)