background image

 

  

 

 

13 

   

 

Ordercode: 33090 

Performer Profile Mini MKII 3200K 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support. 
 
Important:  Fixtures on a serial data link must be daisy-chained in a single line. To comply with the  

EIA-485 standard, no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of fixtures on a DMX data link: 30 fixtures 
Maximum recommended number of fixtures on a power link @ 110V: 70 fixtures 
Maximum recommended number of fixtures on a power link @ 230V: 145 fixtures 

 

Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 
DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. 
Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m), 
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m), 
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m). 

 

DAP Audio data cable FL08 DMX/AES-EBU, XLR/M 5-pin > XLR/F 5-pin. Ordercode FL08150 (1,5 m), 
FL083 (3 m), FL086 (6 m), FL0810 (10 m), FL0820 (20 m). 

 

DAP Audio DMX adapter: 5-pin/3-pin. Ordercode FLA29. 

 

DAP Audio DMX adapter: 3-pin/5-pin. Ordercode FLA30. 

 

DAP Audio DMX Terminator 3-pin. Ordercode FLA42. 

 

DAP Audio DMX Terminator 5-pin. Ordercode FLA43. 

 
 

DMX Channels 

 
1 channel 
 
Channel 1 – Dimmer intensity 
0–255 

Gradual adjustment, from dark to brightest 0–100 % 

 
 

 

Summary of Contents for Performer Profile Mini MKII 3200K

Page 1: ...Performer Profile Mini MKII 3200K V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33090 MANUAL ENGLISH...

Page 2: ...n 8 Lens Locations 9 Focusing the Beam 9 Gobo Slot 9 Color Frame Retaining Clip 10 Shaping the Beam 10 Rotating the Barrel 10 Control Modes 11 Manual Dimmer Control 11 Manual Dimmer Setup 11 Multiple...

Page 3: ...xhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If i...

Page 4: ...east 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug b...

Page 5: ...ead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging tru...

Page 6: ...o the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER N...

Page 7: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Page 8: ...Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Housing Die cast aluminum Cooling Forced convection Color Black IP rating IP20 Dimensions 150 x 106 x 225 mm LxWxH W...

Page 9: ...supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject t...

Page 10: ...ed tighten the beam focus controls Fig 04 Gobo Slot The gobo slot is located on the top of the barrel and is supposed to accommodate the gobo holder 33086 When the slot is not in use a small sheet met...

Page 11: ...by pushing it sideways until it opens 02 Insert the color frame s 03 Lock the retaining clip by pushing it to the initial position until it is secured Fig 06 Shaping the Beam You may shape the beam wi...

Page 12: ...des for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 Turn the manual dimmer control...

Page 13: ...er devices 04 Link the units as shown in fig 09 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourt...

Page 14: ...wn cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio...

Page 15: ...ipe the reflector 05 Insert the barrel into the reflector housing with the gobo slot on top line up the triangles on both parts 06 While pressing in gently rotate the barrel by 45 clockwise until it s...

Page 16: ...MX cable or connectors a controller malfunction a light effect DMX card malfunction 01 Check the DMX setting Make sure that DMX addresses are correct 02 Check the DMX cable Unplug the unit change the...

Page 17: ...anual DMX RDM Lux 1 m 15000 19 Color rendering 90Ra Color temperature 3200K Housing Die cast aluminum Connections Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Col...

Page 18: ...17 Ordercode 33090 Performer Profile Mini MKII 3200K Notes...

Page 19: ...18 Ordercode 33090 Performer Profile Mini MKII 3200K...

Page 20: ...2019 Showtec...

Reviews: