background image

 

  

 

 

   

 

Ordercode: 33037 

Performer 2000 Fresnel DDT MKII 

 

If the external cable is damaged, it has to be replaced by a qualified technician.

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the device. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

Note: WARRANTY on batteries is only 6 months after date of purchase. 

 

When your battery remains flat after fully charging or it doesn’t function or doesn’t charge anymore, 
you can order a new battery. The spare part number for the battery is on request. 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. (T

his distance may differ depending on the model. The exact minimum distance will be 

mentioned in the corresponding manual.)

 

 

To eliminate wear and improve lifespan, during periods of non-use, completely disconnect from 
power via breaker or by unplugging. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40°C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 

Rigging 
Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !
 

 

 

Summary of Contents for Performer 2000 Fresnel DDT MKII V2

Page 1: ...Performer 2000 Fresnel DDT MKII V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33037 MANUAL ENGLISH...

Page 2: ...rmers DMX Control 14 Fixture Linking 15 Data Cabling 15 Control Panel 16 Control Mode 16 DMX Addressing 16 Menu Overview 17 Main Menu Options 18 1 Static Color 18 2 Run Mode 19 3 Power Mode 19 4 Addre...

Page 3: ...2 Ordercode 33037 Performer 2000 Fresnel DDT MKII Troubleshooting 25 No Light 25 No Response to DMX 25 Product Specifications 27 Dimensions 28 Notes 29...

Page 4: ...Performer 2000 Fresnel DDT MKII 1 Powercon power cable 1 5m 1 color frame 1 safety cable User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor t...

Page 5: ...leave various parts of the packaging plastic bags polystyrene foam nails etc within children s reach as they are potential sources of danger Never use a LED strip in sealed or hot places Always mount...

Page 6: ...d out by a qualified technician WARRANTY Till one year after date of purchase Note WARRANTY on batteries is only 6 months after date of purchase When your battery remains flat after fully charging or...

Page 7: ...rvicing the device always make sure that the area below the installation site is secured and that there are not any unauthorized people around The device can be mounted to any kind of truss with a cla...

Page 8: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Page 9: ...rendering 90Ra Color temperature 3100K Dimmer 0 100 Dim curve Dimm4 technology 4 presets Strobe 0 20Hz Motorized zoom 13 41 Control modes Stand alone Master Slave DMX 512 Connections 3 pin 5 pin XLR...

Page 10: ...with inclination screw 08 Heat sink bracket 09 Lens plate 10 Lens frame 11 Collecting lens 12 LED board 13 Thermal switch holder 14 Cooling fan 15 Cooling fan frame 16 Air intake grill 17 Motor 18 Mo...

Page 11: ...power connector 100 240V IN 30 3 pin DMX signal connector IN 31 5 pin DMX signal connector IN 32 3 pin DMX signal connector OUT 33 5 pin DMX signal connector OUT 34 PowerCON power connector 100 240V O...

Page 12: ...s make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supp...

Page 13: ...Performer 2000 Fresnel DDT MKII Setting the angle 01 Loosen the adjustment screw do not remove them 02 Tilt the fixture to the desired position 03 Tighten the adjustment screw to secure the fixture i...

Page 14: ...Performers Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin 5 pin XLR cable to connect the Performer The pin...

Page 15: ...ig 07 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug elec...

Page 16: ...fixtures on a Powercon link 6 units 240V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or const...

Page 17: ...e DMX address of the third Performer should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control each Performer correctly If two or more Performers are ad...

Page 18: ...17 Ordercode 33037 Performer 2000 Fresnel DDT MKII Menu Overview...

Page 19: ...n set the static color and the zoom function 01 While in the main menu press the UP DOWN buttons to choose STATIC 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to toggle betw...

Page 20: ...ions may occur When the power supply reaches 80 of the nominal voltage and a DMX signal is received the Performer will be controlled by DMX When the power supply is below 80 of the nominal voltage and...

Page 21: ...RATE Refresh rate 6 1 Safety Key 01 When the display shows KEY press the ENTER button to open the menu 02 Press the UP DOWN buttons to toggle between ON and OFF to activate deactivate the safety lock...

Page 22: ...hrough the 3 channel modes UNO 1 channel mode DOS 2 channel mode STD P 5 channel mode 6 7 Save DMX Blackout 01 When the display shows DMX ERROR press the ENTER button to open the menu 02 Press the UP...

Page 23: ...er to access the menu Press the buttons in the following order UP DOWN UP DOWN and press the ENTER button to confirm 04 You can choose between Pose1 or Pose2 05 Press the ENTER button again to open th...

Page 24: ...mer 0 255 0 100 dimmer Channel 2 Fine dimmer CH1 must be open 0 255 Fine dimmer adjustment Channel 3 Strobe CH1 must be open 0 9 Strobe OFF 10 99 Strobe ON from low to high frequency 100 109 Strobe OF...

Page 25: ...show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue The Performer 2000 Fresnel DDT MKII requires almost no maintenance However you should keep...

Page 26: ...for replacing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Performer as this may damage the unit...

Page 27: ...connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on t...

Page 28: ...0 Dimming curve Dimm4 technology 4 presets Strobe 0 20Hz Peak intensity 128880cd Color rendering 90Ra Color temperature 3100K Refresh rate 600Hz 25000Hz Housing Die cast aluminium flame retardant plas...

Page 29: ...28 Ordercode 33037 Performer 2000 Fresnel DDT MKII Dimensions...

Page 30: ...29 Ordercode 33037 Performer 2000 Fresnel DDT MKII Notes...

Page 31: ...30 Ordercode 33037 Performer 2000 Fresnel DDT MKII...

Page 32: ...2019 Showtec...

Reviews: