Phase L2 Main Circuit Breakers (MCB) 5 - 8
Each output has its own circuit breaker. Make sure the total load per circuit breaker does not
exceed 16A and the total load per phase does not exceed 32A.
04)
Phase L3 Main Circuit Breakers (MCB) 9 - 12
Each output has its own circuit breaker. Make sure the total load per circuit breaker does not
exceed 16A and the total load per phase does not exceed 32A.
05)
16A Schuko output
Schuko output with a maximum load of 16A, connected to MCB 12, phase L3. Total load for all
sockets together should not exceed 32A per phase.
06)
L1 voltage & amperage LED display
07)
L2 voltage & amperage LED display
08)
L3 voltage & amperage LED display
Backside
Fig. 02
09)
Schuko output
Maximum load 16A. Total load for all sockets on L1 together should not exceed 32A per phase.
10)
Schuko output
Maximum load 16A. Total load for all sockets on L1 together should not exceed 32A per phase.
11)
Multiconnector output (6 outputs, MCB 1, 2, 5, 6, 9 en 10)
Maximum load 10A per output. Total load should not exceed 32A per phase.
12)
Schuko output
Maximum load 16A. Total load for all sockets on L2 together should not exceed 32A per phase.
13)
Schuko output
Maximum load 1x 16A. Total load for all sockets on L2 together should not exceed 32A per phase.
14)
Multiconnector output (6 outputs, MCB 3, 4, 7, 8, 11 en 12)
Maximum load 10A per output. Total load should not exceed 32A per phase.
15)
Schuko output
Maximum load 16A. Total load for all sockets on L3 together should not exceed 32A per phase.