26
Order code: 40102
Polar 300 Hybrid IP65 Moving Head
3. Run Mode
In this menu you can set the control mode of the device.
01)
Press the UP/DOWN buttons to select one of the following 7 options:
●
DMX512:
The device will operate in DMX mode
●
ARTNET:
The device will operate in Art-Net mode
●
ARTNET TO DMX:
The device will receive the data via Ethernet and transmit it via DMX. When
linking multiple devices, the first device can be connected to a computer
with a CAT-5/CAT-6 cable and the rest of the devices can be linked using a
DMX cable
●
sACN:
The device will operate in sACN mode
●
AUTO:
The device will run the built-in program
●
CUSTOM1:
The device will run Custom Program 1. See 5. Edit on pages 30–31 for more
information on how to edit the custom program
●
CUSTOM2:
The device will run Custom Program 2. See 5. Edit on pages 30–31 for more
information on how to edit the custom program
02)
Press the ENTER button to confirm your choice.
4. Option
In this menu you can adjust the device’s settings.
01)
Press the UP/DOWN buttons to scroll through the following 15 options:
02)
Press the ENTER button to confirm your choice.
The available submenus are:
●
PAN INVERT:
Pan direction will be inverted, depending on the position of the Polar
(OFF/ON)
●
TILT INVERT:
Tilt direction will be inverted, depending on the position of the Polar
(OFF/ON)
●
FANS:
Adjustment of the speed of the cooling fans (SLOW, NORMAL, FAST and
AUTO)
●
BLACKOUT:
Output blackout during pan/tilt movement (OFF/ON)
●
DIMMER:
Dimmer speed adjustment: DIM 1, DIM 2, DIM 3, DIM 4 (non-linear dimmers),
OFF (linear dimmer)
●
LED PWM:
Adjustment of the LED’s PWM (Pulse Width Modulation) frequency. The
available options are 1200 Hz, 2400 Hz, 4000 Hz, 6000 Hz, and 25000 Hz
●
DMX ERROR:
Polar’s behavior in case of a DMX error. There are 2 options: SAVE (the Polar
will use the last properly received DMX signal which ensures undisrupted
performance) and BLACK (output blackout)
Summary of Contents for 40102
Page 21: ...20 Order code 40102 Polar 300 Hybrid IP65 Moving Head Menu Overview...
Page 22: ...21 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Page 23: ...22 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Page 24: ...23 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Page 58: ...57 Order code 40102 Polar 300 Hybrid IP65 Moving Head Dimensions...
Page 59: ...58 Order code 40102 Polar 300 Hybrid IP65 Moving Head Notes...
Page 60: ...2019 Showtec...