background image

 

  

 

 

   

 

Ordercode: 950200 

VIBE FX Strike 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showgear device fails to work properly, discontinue the use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Showgear dealer for 
service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The operation of a class 2 laser show laser is only allowed if the show is controlled by a skilled and 
well-trained operator familiar with the data included in this manual. 

 

The user is responsible for correct positioning and operating of the Strike. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

The laser will only work between 10-40ºC. 

 

After 3 hours working, you must shut off the laser and let the laser diode cool off for 30 minutes. 
Otherwise the laser could become damaged and the warranty becomes void. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40°C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others!

 

 

Summary of Contents for 950200

Page 1: ...VIBE FX Strike V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 950200 MANUAL ENGLISH...

Page 2: ...on with the mains 7 Return Procedure 8 Claims 8 Description of the device 9 Overview 9 Backside 10 Installation 10 Set Up and Operation 10 Control Modes 11 One Strike Auto Intelligent 11 One Strike So...

Page 3: ...gear VIBE FX Strike 1 x mounting bracket 2 x mounting screws 5V DC power adapter 1 m IR remote control User manual Safety Instructions Every person involved with the installation operation and mainten...

Page 4: ...life Do not touch the device s housing bare handed during its operation housing becomes very hot Allow the fixture to cool for at least 5 minutes before handling Do not shake the device Avoid brute f...

Page 5: ...y the misuse or incorrect installation of this device This device falls under protection class I Therefore it is essential to connect the yellow green conductor to earth The laser will only work betwe...

Page 6: ...ries can occur instantly it is critical to prevent the possibility of any direct eye exposure According to the laser safety regulation it is not legal to aim Class 2 lasers in areas which people can g...

Page 7: ...nd others require all lasers to be used under the guidelines of ANSI Z136 1 Laser Display guidance can be obtained via the International Laser Display Association www laserist org CAUTION The use of c...

Page 8: ...or safety cable When rigging derigging or servicing the Strike always make sure that the area below the installation site is secured and that there are not any unauthorized people around The VIBE FX...

Page 9: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 10: ...rol modes Auto Sound Intelligent Housing Metal flame retardant plastic IP rating IP 20 Dimensions 107 x 105 x 90 mm LxWxH Weight 0 2 kg Overview Fig 01 01 Mounting bracket 02 Laser lens 03 MODE button...

Page 11: ...Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification volt...

Page 12: ...c power supply socket 04 Turn on the music If the device is set to sound control then the Strike will react to the beat of the music Please see page 12 for more information about the sound control opt...

Page 13: ...hnical installations are to be inspected by an expert after every year in the course of an acceptance test The operator has to make sure that safety related and machine technical installations are to...

Page 14: ...f the above appears to be O K plug the unit in again 04 If you are unable to determine the cause of the problem do not open the Strike as this may damage the unit and the warranty will become void 05...

Page 15: ...er 100mW 80mW 650nm Red 20mW 532nm Green Control modes Auto Sound Intelligent Housing Metal flame retardant plastic Connections Micro USB power adapter IN Laser safety EN IEC 60825 1 Ed 2 2007 03 IP r...

Page 16: ...2017 Showgear...

Reviews: