− 18 −
b) Connection example when using the optional switch with built-in
3SW thermal and a 3m cable)
⑤
Check the rated current shown on the nameplate of the Mistresa and set
the thermal current to the rated current.
Power supply
Terminal box
Thermal protector
Switch
10. Piping
CRM-V series Mistresas do not use a duct hose or drain tube, so neither
needs to be connected to the unit.
Connect the Mistresa directly to the machine/equipment.
(1)
Duct hose material
Because the life of the duct hose will vary according to the type of mist
being sucked in, the use of an oil-resistant duct hose is recommended.
(2)
Intake duct piping
①
A flexible duct (optional item) should be used to facilitate easy duct
maintenance and vibration resistance.
②
The duct should be somewhat longer than strictly necessary (slight
length surplus), but it must not sag when connected.
③
Use the duct companion flange (accessory item) to facilitate easy
connection.
OK example
OK
OK
Mist generation source
Mist generation source
NG example
NG
Mist generation source
Sagging (drain will accumulate here)
(cable 3m)
}
Summary of Contents for Mistresa CRH Series
Page 16: ...14 Mistresa CRM V Installation Dimensions CRM H02 V CRM H04 V CRM H07 V CRM H15 V CRM H22 V...
Page 36: ...CRM H02 S 34 CENTROID POSITION...
Page 37: ...CRM H04 S CRMH H04 S 35 CENTROID POSITION...
Page 38: ...CRM H07 S CRMH H07 S 36 CENTROID POSITION...
Page 39: ...CRM H15 S CRMH H15 S 37 CENTROID POSITION...
Page 40: ...38 CRM H22 S CRMH H22 S CENTROID POSITION...
Page 41: ...39 CRM H02 V CENTROID POSITION...
Page 42: ...40 CRM H04 V CENTROID POSITION...
Page 43: ...41 CRM H07 V CENTROID POSITION...
Page 44: ...42 CRM H15 V CENTROID POSITION...
Page 45: ...43 CRM H22 V CENTROID POSITION...
Page 46: ...44 CRH 100T CENTROID POSITION...
Page 47: ...45 CRH 200T CENTROID POSITION...