(3) Using the burnout prevention terminals
The CRM-S, CRM-V, and CRMH-S Series Mistresa have a heat-sensitive
thermal protector at the motor winding. This auto reset thermal protector
operates as follows. When the motor winding temperature rises
excessively high, the relay contacts open. When the temperature comes
back down to a certain temperature, the contacts automatically close
again. Connect the thermal protector with the terminals A and B for
burnout prevention.
By connecting this terminal in series with the operating circuit of the
electromagnetic switch (with thermal relay), to prevent motor burnout.
CAUTION
①
Be sure to connect the "A" and "B" terminals to the operation circuit
in order to protect the motor.
②
Use the prescribed or lower contact rating (115V AC, 18A / 230V
AC, 13A / 24V DC, 18A).
③
When the thermal relay is tripped, correct the cause, then press the
[RESET] button.
④
The thermal relay may be erroneously tripped if the Mistresa is operated
in an intermittent manner. In this case, change the thermal relay.
a) Connection example for burnout prevention terminals "A" and "B"
Electromagnetic switch device (with thermal relay) Please prepare.
Power supply
When using
an electromagnetic
switch
Terminal box
Thermal protector
THR
MC
THR
MC
ON
OFF
MC
Summary of Contents for Mistresa CRH Series
Page 16: ...14 Mistresa CRM V Installation Dimensions CRM H02 V CRM H04 V CRM H07 V CRM H15 V CRM H22 V...
Page 36: ...CRM H02 S 34 CENTROID POSITION...
Page 37: ...CRM H04 S CRMH H04 S 35 CENTROID POSITION...
Page 38: ...CRM H07 S CRMH H07 S 36 CENTROID POSITION...
Page 39: ...CRM H15 S CRMH H15 S 37 CENTROID POSITION...
Page 40: ...38 CRM H22 S CRMH H22 S CENTROID POSITION...
Page 41: ...39 CRM H02 V CENTROID POSITION...
Page 42: ...40 CRM H04 V CENTROID POSITION...
Page 43: ...41 CRM H07 V CENTROID POSITION...
Page 44: ...42 CRM H15 V CENTROID POSITION...
Page 45: ...43 CRM H22 V CENTROID POSITION...
Page 46: ...44 CRH 100T CENTROID POSITION...
Page 47: ...45 CRH 200T CENTROID POSITION...