-13-
Model W1842 (For Machines Mfd. Since 6/17)
EL
EC
TR
IC
A
L
Voltage.Conversion.to.
220V
The voltage conversion MUST be performed by an
electrician or qualified service personnel.
The voltage conversion procedure consists of rewiring the
motor and installing the correct plug. A wiring diagram is
provided on
Page.58
for your reference.
IMPORTANT: If the diagram included on the motor
conflicts with the one on
Page 58
, the motor may have
changed since the manual was printed. Use the diagram
provided on the motor junction box instead.
Items.Needed.
Qty
• Phillips Head Screwdriver #2 ............................1
• Electrical Tape ................................. As Needed
• Wire Nut (14 AWG x 3) ....................................1
• 6-15 Plug ....................................................1
• Wire Cutters/Stripper.....................................1
To.convert.Model.W1842.to.220V,.do.these.steps:
1..
DISCONNECT MACHINE FROM POWER!
2.
Cut off existing 5-15 plug.
3..
Remove front cabinet cover and motor junction box,
remove two wire nuts indicated in
Figure.5
,
.
then
disconnect wires.
4.
Use wire nuts to connect wires as indicated in
Figure.6
. Twist wire nuts onto their respective wires
and wrap them with electrical tape so they will not
come loose.
5.
Close and secure motor junction box.
6..
Install a 6-15 plug according to manufacturer's
instructions. If plug manufacturer's instructions are
not available, NEMA standard 6-15 plug wiring is
provided on
Page.58
.
Figure.5.
Inside motor junction box (motor
pre-wired to 120V).
Figure.6.
Motor rewired to 220V.
Rewired to 220V
Ground
Start
Capacitor
300uF
125VAC
MOTOR 110V
Ground
Rewired to 220V
Ground
Start
Capacitor
300uF
125VAC
MOTOR 110V
Ground
To Switch
Remove
Wire
Nuts and
Disconnect
Wires
Connect Wires
and Secure
with Nuts
Summary of Contents for W1842
Page 65: ...Model W1842 For Machines Mfd Since 6 17...