INSTRUCTION MANUAL

Infrared Temperature Sensor

RD-500 SERIES

No. RD51E2

2012.02

Preface

Thank you for purchasing our Infrared Temperature Sensor RD-500 series. This manual contains instructions
for the mounting, functions, operations and notes when operating the RD-500. To ensure safe and correct use,
thoroughly read and understand this manual before using this sensor. To prevent accidents arising from the
misuse of this sensor, please ensure the operator receives this manual.

Caution

• This sensor should be used in accordance with the specifications described in the manual.

If it is not used according to the specifications, it may malfunction or cause a fire.

• Be sure to follow all of the warnings, cautions and notices. If they are not observed, serious injury or malfunc-

tion may occur.

• The contents of this instruction manual are subject to change without notice.
• Care has been taken to assure that the contents of this instruction manual are correct, but if there are any

doubts, mistakes or questions, please inform our sales department.

• This instrument is designed to be used in close proximity with the object to be measured. Measures must be

taken to ensure that the operator cannot touch power terminals or other high voltage sections.

• Any unauthorized transfer or copying of this document, in part or in whole, is prohibited.
• Shinko Technos CO., LTD. is not liable for any damage or secondary damage(s) incurred as a result of using

this product, including any indirect damage.

Safety Precautions

(

Be sure to read these precautions before using our products.

)

The safety precautions are classified into categories: “Warning” and “Caution”. Depending on the circumstances,

procedures indicated by

Caution may be linked to serious results, so be sure to follow the directions for usage.

Warning

Warning

• To prevent an electric shock or fire, only Shinko or other qualified service personnel may handle the

inner assembly.

• To prevent an electric shock, fire or damage to the instrument, parts replacement may only be

undertaken by Shinko or other qualified service personnel.

Safety Precautions

• To ensure safe and correct use, thoroughly read and understand this manual before using this

instrument.

• This instrument is intended to be used for industrial machinery, machine tools and measuring

equipment. Verify correct usage after purpose-of-use consultation with our agency or main office.
(Never use this instrument for medical purposes with which human lives are involved.)

• External protection devices such as protective equipment against excessive temperature rise, etc.

must be installed, as malfunction of this product could result in serious damage to the system or
injury to personnel. Also proper periodic maintenance is required.

• This instrument must be used under the conditions and environment described in this manual. Shinko

Technos Co., Ltd. does not accept liability for any injury, loss of life or damage occurring due to the
instrument being used under conditions not otherwise stated in this manual.

Caution with Respect to Export Trade Control Ordinance

To avoid this instrument from being used as a component in, or as being utilized in the manufacture of
weapons of mass destruction (i.e. military applications, military equipment, etc.), please investigate the
end users and the final use of this instrument. In the case of resale, ensure that this instrument is not
illegally exported.

Caution

Procedures which may lead to dangerous conditions and cause death or serious
injury, if not carried out properly.

Procedures which may lead to dangerous conditions and cause superficial to
medium injury or physical damage or may degrade or damage the product, if not
carried out properly.

Summary of Contents for RD-500 Series

Page 1: ...e sure to follow the directions for usage Warning Warning To prevent an electric shock or fire only Shinko or other qualified service personnel may handle the inner assembly To prevent an electric shock fire or damage to the instrument parts replacement may only be undertaken by Shinko or other qualified service personnel Safety Precautions To ensure safe and correct use thoroughly read and unders...

Page 2: ...nsparent plastic etc In case measurement is difficult it can be made easier if black body tape is used to raise emissivity 3 Installation Ensure the installation location corresponds to the following conditions The sensing head should be kept as close as possible to the object The ambient temperature of this sensor should not exceed 70 158 The sensor lens should be protected from being covered wit...

Page 3: ...x the mounting bracket with screws at the installation location Please have screws ready Recommended size M4 2 Remove the mounting nut and fasten the nut again after inserting the sensor into the hole of the mounting bracket 1 Fix the mounting bracket with screws at the installation location Please have screws ready Recommended size M4 2 Remove the mounting nut and fasten the nut again after inser...

Page 4: ...rge collar to the sensor and fasten it Please carefully set aside the mounting nut 3 Connect a tube connector or pump to the air purge collar 1 Remove the mounting nut 2 After inserting the sensor into the hole of the mounting bracket insert the air purge collar to the sensor and fasten it Please carefully set aside the mounting nut 3 Connect a tube connector or pump to the air purge collar 4 Wiri...

Page 5: ...TA will not be necessary Fig 4 2 2 5 Operation Attention If ambient temperature is rapidly changing leave the sensor for more than 20 minutes as it is then measure the temperature Do not measure temperature near a large magnetic field example Arc welding machine induction heater etc Measurement errors will be caused due to electromagnetic disturbance After completing installation for the object to...

Page 6: ...r is greater Repeatability 0 5 of reading or 0 5 whichever is greater Emissivity Fixed at 0 95 0 200 to 1 000 When the emissivity adjuster PTA sold separately is used 0 200 to 1 000 When the digital indicating controller ACS 13A A sold separately is used Response 240ms 90 response Spectral Range 8 to 14 m Max Load Resistance 900 DC current output for 24V DC 6 5 Other Ambient Temperature 0 to 70 Am...

Page 7: ...or the RD 502 RD 515 Setting emissivity for the RD 5CF Power supply for the RD 500 RDP 24 Safety Standards RoHS directive compliant CE marking compliant 7 External Dimensions Scale mm RD 502 M0 RD 515 M0 RD 515 H0 Nut Accessories Included Fig 7 1 RDP 18 M16 1 12 103 1000 18 M16 1 18 4 21 ...

Page 8: ...on the lens Always keep the lens clean Foreign particles on the lens affect measurement accuracy Inquiries For any inquiries about this unit please contact our agency or the vendor where you purchased the unit after checking the model and serial number In addition to the above please let us know the details of the malfunction or discrepancy and the operating conditions 18 M16 1 12 103 1000 18 M16 ...

Reviews: