![Shinko ACD-13A Instruction Manual Download Page 14](http://html.mh-extra.com/html/shinko/acd-13a/acd-13a_instruction-manual_1258167014.webp)
- 14 -
3.3 CT (Current Transformer) External Dimensions (Scale: mm)
CTL-6-S-H (for 20 A)
CTL-12-S36-10L1U (for 100 A)
(Fig. 3.3-1)
3.4 Mounting to and Removal from the Control Panel
(Common to ACD-13A, ACR-13A)
Caution
As the case is made of resin, do not use excessive force while screwing in
the mounting bracket, or the case or mounting brackets could be damaged.
The torque should be 0.12 N•m.
How to mount the unit
Mount the controller vertically to the flat, rigid panel to ensure it adheres to the
Drip-proof/Dust-proof specification (IP66).
Mountable panel thickness: 1 to 8 mm
(1) Insert the controller from the front side of the panel.
(2) Attach the mounting brackets by the holes at the top and bottom of the case,
and secure the controller in place with the screws.
How to remove the unit
(1) Turn the power to the unit OFF, and disconnect all wires before removing the unit.
(2) Loosen the screws of the mounting brackets, and remove the mounting brackets.
(3) Pull the unit out from the front of the panel.