6.  Message of status and error 

 
 
 
 

The lower limit was reached. 
“PUSH LMT” is blinking. 

If the status is abnormal, move the 
lower limit switch position. 

 
 
 
 

The upper limit was reached. 
“PULL LMT” is blinking. 

If the status is abnormal, move the 
upper limit switch position. 

 
 
 
 

The over load of the mounted force gauge 
occurred in push direction. 

Confirm  whether  the  force  gauge 
used is correct. 
Check  whether  the  measurement 
is an abnormal. 

 
 
 
 

The over load of the mounted force gauge 
occurred in pull direction. 

Confirm  whether  the  force  gauge 
used is correct. 
Check  whether  the  measurement 
is an abnormal. 

 
 
 
 

The emergency stop was pushed. 

Confirm  that  an  abnormal  is  not 
found, then release the emergency 
stop. 

 
 
 
 

The motor  or  the  driver  of  the motor  was 
abnormal. 

Turn off and wait one minute, then 
turn on. 
Contact TECHNICAL SUPPORT  if 
the alarm is not canceled. 

 
 
 
 

The  communication  error  between  the 
controller and the motor driver in the stand 
occurred. 

Turn off and wait one minute, then 
turn on. 
Contact  to  our  technical  support  if 

the error alarm is not canceled. 

 
 
 
 
 
 

The read error of the memory in the stand 
occurred. 

Turn off and wait one minute, then 
turn on. 
If  the  error  is  not  canceled, 
initialize  the  parameter.  Refer  to 
the  below  procedure  of  the 
initialization. 

 
 
 
 
 
 

The write error of the memory in the stand 
occurred. 

Turn off and wait one minute, then 
turn on. 
If  the  error  is  not  canceled, 
initialize  the  parameter.  Refer  to 
the  below  procedure  of  the 
initialization. 

 
 
 
 
 
 

The  stand  could  not  recognize  the 
mounted force gauge. 

Check: 
The parameters setting of the force 
gauge,  the  sequence  of  power  on 
and the cable. 
If no problem, ask to our technical 
support. 

 

10 

Summary of Contents for FGS-100VC

Page 1: ...97591A FGS VC Series Motorized Stand Operation Manual Read Manual thoroughly prior to operation Use instrument only after reading the complete manual Follow all safety precautions...

Page 2: ...FGS VC falls on your foot it leads to serious injury Do not use in atmosphere with the ignition and the explosion hazard Never use in oils and fats and the flammability gas atmosphere etc with the ign...

Page 3: ...with ignition and explosion hazard Place where vibration such as machines is received Operate without 32 104 F 0 40 C Cleaning with thinner and gasoline etc Note drawing the cable so that the force ga...

Page 4: ...to PC Connection to PC Connection to PC Connection to PC and the stand and the stand and the stand and the stand 5 5 5 5 5 Operation Operation Operation Operation 5 5 1 5 1 5 1 5 1 Basic operation flo...

Page 5: ...FGP EX series Confirm the following procedures before use 1 2 Confirmation of product packing FGS VC 1 Cable to force gauge 1 Cable clip 1 USB cable 2m 1 Hex head spanner 1 Bolt M8 x 8mm 4 Socket bol...

Page 6: ...ation 2 Speed key up 3 Speed key Down The moving speed is increase or decrease when pushing Up or Down key If the key keeps to push the speed increases decreases continuously 4 MAX key The moving spee...

Page 7: ...LCD display Displays distance speed and mode etc LCD display 4 Setup 4 1 Installation of force gauge The force gauge that can be connected with FGS VC is FGP series and FGP EX series The force gauges...

Page 8: ...arameter setting of the force gauge Set the following parameters Measurement polarity RS232C baud rate 19 200 bps Refer to the manual of the force gauge Connect to FGS VC Connect the force gauge to FG...

Page 9: ...is described as follows Personal computer USB cable Cable between FGS VC and force gauge Force gauge power Turn on the power of the force gauge Keep hands hair and jewelry away from stand when drive a...

Page 10: ...urement purpose and the usage Mode can be changed by Mode switch Start to measure Start each mode by pressing PUSH PULL or START switch Refer to each mode section FGS VC is able to test as follows Com...

Page 11: ...on of PULL limit by pressing PULL switch You want to move only while you press the PUSH key You want to move the round trip operation many times between limits of PUSH and PULL etc Select manual opera...

Page 12: ...ted direction until one of the following occurs STOP button is pushed one of the manual limit switches is tripped the emergency reset button is pushed MANU mode When pressing the PUSH PULL key FGS VC...

Page 13: ...If you want to cancel the setting press ZERO button 5 3 2 JOG mode Contents This mode of operation is identical to MANU mode except that the movement in any direction will only occur while either the...

Page 14: ...stopping Pressing SET button and the speed can be changed by UP or DOWN key of the SPEED Then press SET button for saving If you want to cancel the setting press ZERO button Setting speed The UP or D...

Page 15: ...PULL button is selected The stand will continue to move until one of the following events occurs the STOP button is pushed one of the manual limit switches is tripped the emergency reset button is pu...

Page 16: ...so the speed is able to be changed while moving Display Repeat count Incremental count at pressing PUSH or PULL button The count is cleared with the ZERO button When the mode is changed the count will...

Page 17: ...d by STOP Finally press SET button for saving If you want to cancel the setting press ZERO button Setting speed The UP or DOWN button of the SPEED can be used to change The range is 10 to 400 mm min S...

Page 18: ...continue to move until one of the following events occurs the STOP button is pushed the emergency reset button is pushed Display alternately B A Upper limit Lower limit PULL Stop with upper limit swi...

Page 19: ...so the speed is able to be changed while moving Display Repeat count Incremental count at pressing PUSH or PULL button The count is cleared with the ZERO button When the mode is changed the count will...

Page 20: ...ZERO button Setting speed The UP or DOWN button of the SPEED can be used to change The range is 10 to 400 mm min Setting dwell timer The STOP button of the dwell time can be used to change Pressing ST...

Page 21: ...e when START button is pressed The stand will continue to move until one of the following events occurs the STOP button is pushed one of the manual limit switches is tripped the emergency reset button...

Page 22: ...operation is shown below Detect point Start point Start point Dwell timer P1 P3 P3 Dwell timer Return to Start point Return to Start point Dwell timer Present position Moving direction Operation stat...

Page 23: ...he parameter is the direction of moving from Start point to Detect point The STOP button can be changed to Push or Pull alternately Detect object The force for detecting object can be set by PUSH or P...

Page 24: ...ter is the speed setting for moving from Start point to Detect point The UP or DOWN button of the SPEED can be used to change SET SET Dwell timer at P5 The parameter is the dwell timer Pressing STOP t...

Page 25: ...the programmed Detect object should be 0 4lb 200lb x 0 2 5 5 Parameter setting mode The relations function is set to the entire stand Contents The parameters are shown in the below table Items Descrip...

Page 26: ...button can be used to change Pressing the button the setting will be changed alternately SET MODE Saving and go to MANU mode MODE Saving and go to MANU mode Acceleration The UP or DOWN button can be...

Page 27: ...f the motor was abnormal Turn off and wait one minute then turn on Contact TECHNICAL SUPPORT if the alarm is not canceled The communication error between the controller and the motor driver in the sta...

Page 28: ...wait one minute 2 Press ZERO and SET button both turn on in keeping to press these buttons 7 Dimensions FGS 100VC 2 95 3 94 19 69 Lower limit Upper limit inch 4 72 Emergency switch Operation panel 2 9...

Page 29: ...1 18 7 87 5 91 M8 mm 0 39 1 26UNF M10 mm 1 77 0 79 3 94 5 51 1 97 2 0 35 0 35 2 95 1 95 2 26 1 20 5 91 3 0 22 4 0 18 1 57 Plate FGS 100VC 0 79 0 79 1 18 5 91 Table Adjust FGS 100 250VC 7 87 1 77 adju...

Page 30: ...250VC 3 54 0 49 0 43 2 95 0 28 0 20 2 76 Stroke 15 75 4 72 3 23 0 75 38 84 Operation panel Emergency switch Lower limit Force gauge FGS 250VC Force gauge FGPX 250H 11 81 2 95 2 95 Upper limit 3 94 4...

Page 31: ...bleshooting The following are general checkpoints please call your local Shimpo representative or contact Shimpo Instruments directly for further assistance Even if the power supply is turned on LCD d...

Page 32: ...uments s option Shimpo Instruments reserves the right to satisfy warranty obligation in full by reimbursing Buyer for all payments made to Shimpo Instruments whereupon title shall pass to Shimpo Instr...

Reviews: