![Shihlin electric SDP Series Manual Download Page 92](http://html.mh-extra.com/html/shihlin-electric/sdp-series/sdp-series_manual_1256844092.webp)
79
3.9.5 1PG wiring diagram
PP
8
NP
6
CR
19
VCC
1
、
26
OP
40
FP
COM0
RP
CLR
COM1
PG0+
PG0-
S/S
DOG
STOP
VIN
SD
Metal
casing
OPC
7
X6
X7
X10
X11
X12
X1
X2
X3
X4
X5
L
N
24V
0V
S/S
X0
A(F)X2N-1PG
stop
DOG
servo ALM
In-position ready INP
ready RD
start
homing
JOG-
JOG+
LSN
LSP
stop
abnormal reset
extend connect
cable
Note1: if the DC24V power provided by PLC is applied, the VDD and COM+ cannot be short-circuited.
Note2: due to A(F)X2N-1PG preset pulse type is negative logic/forward reverse pulse train, PA13
should set to 0010 if preset pulse type is applied.
Note3: please refer to user manual for regenerative resistor and brake control unit wiring.
Note4: please refer to user manual for digital output DO of sink type or source type wiring.
24
、
25
、
50
SG
SG
24
、
25
、
50
A(F)X2N PLC
SG
SG
LSP
DI7
DI6
DI5
DI4
DI3
DI2
DI1
LSN
DI8
CN1
22
20
19
18
17
16
15
14
23
21
SG
24
、
25
、
50
DI11
12
DI12
13
TL1
CDP
RES
PC
CM1
SON
TL
CR
EMG
LOP
LSP
LSN
COM+
49
DO2
DO1
VDD
DO5
DO4
DO3
RA1
RA3
RA2
RA5
RA4
CN1
42
41
48
45
44
43
RA6
DO6
46
INP
WNG
ZSP
RD
TLC
ALM
DOCOM
47
SG
24
、
25
、
50
Encoder
CN2
R
L1
L2
T
S
MC
MCCB
P
PE
D
W
V
U
C
SD
N
Servo Drive
There-phase
AC200V~240V
regenerative
resistor(note3)
Servo motor
less than 10m
digital output
common terminal
(note4)
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...