5. Now plug the network plug into the socket again and switch the pump on again.
6. If the intake nozzle gets stuck on solids, first turn off the pump, then pull the power plug
and remove the solids from the intake nozzle.
7. Pump the liquid until the pump intakes air. Switch the pump off again.
As the intake nozzle reach until about 1 cm above the ground, it is possible that there are
still floating solids in this gap. For this reason, only use the low-level pumping device of the
pump for draining residual water.
4.5 Low-level pumping at low water level
The following two methods can be used to start the pump even if the water level is low
(< 15 cm):
4.5.1 Flat intake nozzle with integrated non-return flap
Mount the flat intake nozzle with integrated non-return
flap (available as an accessory) as described under
4.4 on the intake side of the pump (see image 2.4). Fill
the pump with water. The integrated non-return flap
holds the water in the pump. On starting the pump, the
non-return flap opens automatically and the pump be-
gins the low-level pumping operation.
4.5.2 Glove trick
To this end, pull a disposable glove (sterile glove, latex glove) over the flat intake nozzle
of the pump and mount it as described under 4.4 on the intake side of the pump. Fill the
pump with water. The dispo
sable glove acts as a “non-return flap” and keeps the water in
the pump. On starting the pump, the disposable glove tears and the pump begins the low-
level pumping operation.
4.6 Deep-level pumping
In case of a depression (pump sump, gully, etc.) deep-level pumping can be carried out
additionally. Please observe the following points:
1. Pump the medium according to section 4.2 of this user manual with the intake nozzle
facing upwards until the pump intakes air.
2. Now switch the pump off and remove the motor protection plug. Secure the pump and
the motor protection plug against accidental restarting and plugging.
Danger from electric shock:
Only carry out work on the pump when the pump is disconnected from the network by
removing the motor protection plug from the power supply. Prevent accidental restart
and plugging of the pump and the motor protection plug by taking appropriate measures.
3. Mount the intake nozzle with the opening facing
downwards on the coupling on the inlet side of the
pump. Use a coupling spanner for this.
4. Open both locks of the flap bracket and flap the flap
bracket under the pump. Place the pump at the de-
pression (see image 3.2).
5. Now plug the motor protection plug into the socket
again and switch the pump on again.
6. Pump the liquid until the pump intakes air. Switch the pump off again.
Image 3.1: Mini-CHIEMSEE flat intake nozzle
with integrated non-return flap
Image 3.2:
Deep-level pumping