![Shenzhen Seener Wireless Technology SW8021 Datasheet Download Page 7](http://html.mh-extra.com/html/shenzhen-seener-wireless-technology/sw8021/sw8021_datasheet_1256100007.webp)
SW8021 LoRaWAN Gateway Module Datasheet V1.0.0
Shenzhen Seener Wireless Technology Co., Ltd
- 3 -
2.4
Operating conditions
All specifications are at an ambient temperature of 25
°
C. Extreme operating temperatures can
significantly impact specification values. Applications operating near the temperature limits should be
tested to ensure the specification.
Table2.4 operating temperature range
Operating beyond the specified operating conditions can affect device reliability.
2.5
Operating conditions
2.5.1 Power Supply Range
The table below lists the power supply range. Input voltage at 3.3Vaux must be above the normal operating
range minimum limit to switch-on the module.
Table2.5.1 Operating power supply range
Operating beyond the specified operating conditions can affect device reliability.
2.5.2 Power Consumption
Mode
Condition
Min.
Typical
Max.
Active-Mode(TX) The power of TX channel is 15.90dBm and 3.3V supply.
500mA
520mA
550mA
Active-Mode(RX )
TX disabled and RX enabled.
70mA
85mA
105mA
Table2.5.2 Working current
2.6
RF Characteristics
The following table gives typically sensitivity level of the SW8021 .
Signal Bandwidth/[kHz]
Spreading Factor
Sensitivity/[dBm]
125
SF12
-139
125
SF10
-134
125
SF7
-125
125
SF5
-121
GFSK_50
50 kbps, GFSK modulation
-111
250
SF9
-124
Parameter
Min.
Typ
Max.
Unit
Remarks
Normal operating
temperature
-40
+25
+85
°
C
Normal operating temperature range
Symbol
Parameter
Min.
Typical
Max.
Unit
3.3V
Module supply operating input voltage
3.00
3.30
3.60
V