RF Wireless Receiver (Model 0020348 S1DA-DC12)
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, w ater and air, such as remote control lights, sirens, locks,
motors, fans, w inches, blinds, linear actuators, doors, w indow s, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Waterproof: The receiver has w aterproof case and w aterproof connector, it can be installed outdoors.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminal is NO / NC (normally open / normally
closed), w hich serves as a sw itch. That means you should also connect a separate pow er supply to it.
With w
ired control terminal
s: You can connect sensors, limit sw itches, manual sw itches or external devices to control the receiver.
Adjustable delay time: 0 seconds ~ 99 hours
Design w ith low -pow er and high-speed CMOS technology.
You can turn on/ off the receiver w ith transmitter (remote control) from any place w ithin a reliable distance.
Wireless RF signal can pass through w alls, floors, doors or w indow s.
With reverse pow er protection and over current protection.
Reliable control: The receiver only w orks w ith the transmitter w hich use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use tw o or more units in the same place.
Receiver:
Model No.: S1DA-DC06 / S1DA-DC09 / S1DA-DC12 / S1DA-DC24
Pow er Supply (Operating Voltage): DC6V (S1DA-DC06), DC9V±1V (S1DA-DC09), DC12V±1V (S1DA-DC12), DC24V±1V (S1DA-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Transmitting Frequency: 315MHz / 433MHz
Channel: 1 CH
Control Mode: Delay (Press -> ON; Then OFF after the delay time)
Adjustable delay time: 0 seconds ~ 99 hours
Maximum Working Current: 10A / each channel
Static Current: ≤6mA
PCB size: 140mm x 73mm x 18mm
Case size: 192mm x 100mm x 45mm
Work w ith Fixed code transmitters or Learning code transmitters.
Matching Transm itters:
The receiver can w ork w ith different transmitters, such as model C-1 / C-2 (100M), CWB-1 / CWB-2 (50M, w aterproof), CP-1 / CP-2 /CV-2(500M), or
CB-1 / CB-2 (1000M), CBW-1 / CBW-2 (1000M, w aterproof) etc.
Working Range:
With a transmitter (such as C-2) to form a complete set, the w orking distance can reach 100M in an open ground. The maximum w orking distance
100M is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it w ill be hindered by trees,
w alls or other constructions, and w ill be interfered by other w ireless signals. Therefore, the actual distance may or may not reach 100M. If you w ant to
have a further w orking range, you can install an external antenna to the receiver, and you also can use a pow erful transmitter, such as CB
transmitters.
Usage (with the transmitter C-2):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC pow er output. Initial state of relay output terminals: Terminals A and B are Normally Open; Terminals A
and C are Normally Closed.
If you w ant to control a DC 12V lamp, do as follow ing:
1) Connect the positive pole of DC
pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”.
2) Connect terminal C to the positive pole of DC pow er supply, connect terminal B to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC pow er supply.
If you w ant to control an AC 220V lamp, do as follow ing:
1) Connect the positive pole of DC
pow er supply to terminal “L / +”, and connect the negative pole of DC pow er supply to terminal “N / -”.
2) Connect terminal C to the live w ire of AC pow er supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the
neutral w ire of AC pow er supply.
Press button 1: Turn on relay (connect B and C, disconnect A and B), the lamp is on.
After delay time: Turn off relay by itself (disconnect B and C, connect A and B), the lamp is off.
Press button 2: Turn off relay immediately, no need to w ait for delay time.
Press buttons of
“
+
” and “
-
” on the timer, adjust delay time from 0 second to 99 hours. “H” is Hour, “M” is Minute, and “S” is Second.
For example, if you set “S 0 1”, it means the delay time is 1 second.