Shenlan SMD SERIES Instruction Manual Download Page 1

SMD SERIES INSTRUCTION MANUAL

    

Thank you very much for selecting  the SMD series digital

panel meters, before installing and using, please read the
following instructions in detail.

SHENLAN

·

3

1

/

Digital volt meter

ampere meter

·

4

1

/

2

 

Digital volt meter

ampere meter

·

3

1

/

Digital true RMS volt meter

ampere meter

·

3

1

/

2

4

1

/

2

 

Analog parameter display meter

·

3

1

/

 

Digital ohmmeter

·

3

1

/

Digital Thermometer

·

Digital power factor meter

·

4

/

Digital counter

length meter

·

4

/

6  

Digital tachometer

line speed meter

·

4

/

Digital timer

MAIN FEATURES

VOLT&AMPERE METER,OHMMETER,

      THERMOMETER&ANALOG  DISPLAY METER

1.

7 Segment LED display

,

display height 14.2mm.

2.

Precise leveling circuit is using to measure AC signal .

3.

Power  voltage  DC 5V

(

Options:DC7~12V/DC7~24V

)

4.

Ture RMS series use monolithic true rms-to-dc converter

5.

When groups meters use a same DC power supply,can

   choose power supply and measuring internal isolation model.

3

1

/

MODEL COMPOSITIONS

Measurement range

NAME

---

3

1

/

2

  

Series digital meter

SM3D

VOLT

----

Standard 5VDC power supply

7-12VDC  power supply

H

7-24VDC

 

power supply

F

RANGE

--

4

1

/

MODEL COMPOSITIONS

Measuring range

NAME

----

4

1

/

Series digital  meter

SM5D

VOLT

----

Standard 5VDC Power supply

7-12VDC power supply

H

7-24VDC power suppply

F

SPEC 

---

AV

AC voltage

AA

AC ampere

DV

DC voltage

DA

DC ampere

SA

ampere signal

SX

appointed   signal

SV voltage signal

TECHNICAL  SPECIFICATIONS

Overflow indication

Insulation strength

Dielectric resistance

Ambient humidity

min.100M

Ω

(at 500VDC

)

AC2000V  50/60Hz for 1 Minute

0~50ºC

35%~85%RH

Display Accuracy

±0. 5%F.S±2Digit(AC,

Ω,

ºC)

Display range

Power consumption

Power supply

±1999

(

3

1

/

2

),

±19999

(

4

1

/

2

)

70mA max.(DC5V Power supply)

DC5V±5%(Option:7~12VDC/7~30VDC)

DIsplay method

7 Segment LED display

Sampling Time

Approx. 2.5 times/sec.

Input mode

Measuring voltage/ampere signal

Response time

Approx. 2 sec.(0~max.)

±0. 2%F.S±2Digit(DC)

A/D converter

Max. allowable input

150% For input F.S

-1

or

1

"(

for 3

1

/

2

)

DC VOLTMETER

*

SM3D-TDV input is the same as SM3D-DV.

*

When measure over 1000V,please use divide voltage circuit.

3

1

/

 Model

Input 

F.S

±199.9mV

±1.999V

±19.99V

±199.9V

±600V

divide volt.

SM3D-DV0.2

SM3D-DV2

SM3D-DV20

SM3D-DV200

SM3D-DV600

SM3D-DV1000

SM3D-DV2000

SM3D-DV5000

4

1

/

 Model

Input 

F.S

±199.99mV

±1.9999V

±19.999V

±199.99V

±600.0V

SM5D-DV0.2

SM5D-DV2

SM5D-DV20

SM5D-DV200

SM5D-DV600

SM5D-DV1000

SM5D-DV2000

SM5D-DV5000

AC VOLTMETER

*

SM3D-TAV input is the same as SM3D-AV.

*

When measure over 1000V, please use a P.T

3

1

/

 Model

Input 

F.S

199.9mV

1.999V

19.99V

199.9V
600V

P.T  INPUT

P.T  INPUT

SM3D-AV0.2

SM3D-AV2

SM3D-AV20

SM3D-AV200

SM3D-AV600

SM3D-AV1000

SM3D-AV2000

P.T  INPUT

SM3D-AV5000

4

1

/

2  

Model

199.99mV

1.9999V

19.999V

199.99V

600.0V

P.T  INPUT

P.T  INPUT

SM5D-AV0.2

SM5D-AV2

SM5D-AV20

SM5D-AV200

SM5D-AV600

SM5D-AV1000

SM5D-AV2000

P.T  INPUT

SM5D-AV5000

Input 

F.S

*

SM3D-TDA input is the same as SM3D-DA

.

*

When measure over DC 5A,please use a Shunt(75mV)

AC AMMETER

DC AMMETER

DIGITAL THERMOMETER

*

Thermocouple cold  compensation range :0~50ºC

DIGITAL OHMMETER

PARAMETER DISPLAY METER

 

Measuring various linear voltage,ampere,ohm signal,display

frequency,rotative speed,line  speed,weight ,temperature,
humidity,power,flow,length,percentage etc.

3

1

/

MODEL

INPUT F.S

±1.999uA

±19.99uA

±199.9uA

±1.999mA

±19.99mA

±199.9mA

±1.999A

SM3D-DA2uA

SM3D-DA20uA

SM3D-DA200uA

SM3D-DA2mA

SM3D-DA0.02

SM3D-DA0.2

SM3D-DA2

±5.00A

SM3D-DA5

Shunt    10A/75mV

SM3D-DA10

SM3D-DA20

SM3D-DA30

Shunt    20A/75mV

Shunt    30A/75mV

Shunt    50A/75mV

SM3D-DA50

SM3D-DA100

SM3D-DA200

Shunt    100A/75mV

Shunt    200A/75mV

SM3D-DA1000 Shunt    1000A/75mV

4

1

/

MODEL

INPUT F.S

±19.999uA

±199.99uA

±1.9999mA

±19.999mA

±199.99mA

±1.9999A

SM5D-DA20uA

SM5D-DA200uA

SM5D-DA2mA

SM5D-DA0.02

SM5D-DA0.2

SM5D-DA2

±5.000A

SM5D-DA5

Shunt    10A/75mV

SM5D-DA10

SM5D-DA20

SM5D-DA30

Shunt    20A/75mV

Shunt    30A/75mV

Shunt    50A/75mV

SM5D-DA50

SM5D-DA100

SM5D-DA200

Shunt    100A/75mV

Shunt    100A/75mV

SM5D-DA1000 Shunt    1000A/75mV

SM5D-DA500

Shunt    200A/75mV

199.9uA

1.999mA

19.99mA

199.9mA

1.999A

SM3D-AA200uA

SM3D-AA2mA

SM3D-AA0.02

SM3D-AA0.2

SM3D-AA2

5.00A

SM3D-AA5

SM3D-AA20

SM3D-AA30

C.T 20A/5A

C.T 30A/5A

C.T 50A/5A

SM3D-AA50

SM3D-AA100

SM3D-AA200

C.T 100A/5A

C.T 200A/5A

SM3D-AA1000 C.T 1000A/5A

*

SM3D-TAA

 

input is the same as SM3D-AA

*

When measure over AC 5A, please use a C.T or Shunt

4

1

/

2  

MODEL

INPUT F.S

199.99uA

1.9999mA

19.999mA

199.99mA

1.9999A

SM5D-AA200uA

SM5D-AA2mA

SM5D-AA0.02

SM5D-AA0.2

SM5D-AA2

5.000A

SM5D-AA5

SM5D-AA20

SM5D-AA30

C.T 20A/5A

C.T 30A/5A

C.T 50A/5A

SM5D-AA50

SM5D-AA100

SM5D-AA200

C.T 100A/5A

C.T 200A/5A

SM5D-AA1000 C.T 1000A/5A

BUILT-IN PRECISE C.T AC AMPERE METER

*

*

*

Standard

J

Built-in CT isolation input

H

Hold function

TYPE

----

Temperature

AV
AA

AC Ampere

DV

DA

DC Ampere

TAA

TAV

TRMS AC Voltage

T

TDA

SA Ampere signal

SX

appointed  signal

SV Voltage signal

TRMS AC Ampere

TDV

AC/DC Voltage

Ohm signal

R

SM3D

SM5D

Model

Range

Crossing turns

SM3D-AA20-J

0~19.99A

SM5D-AA20-J

0~19.999A

SM3D-AA5-J

0~5.00A

SM5D-AA5-J

0~5.000A

SM3D-AA2-J

0~1.999A

SM5D-AA2-J

0~1.9999A

C.T  hole  diameter

7mm

5mm

5mm

1

1

2

Model

Range

Temperature sensor

SM3D-TK1

0~200ºC

K Thermocouple

SM3D-TK2

0~400ºC

SM3D-TK3

0~800ºC

SM3D-TK4

0~1200ºC

SM3D-TP1

-100.0~199.9ºC

SM3D-TP2

-200~500ºC

Pt100

Model

Range

0~19.99

Ω

0~199.9

Ω

0~1.999K

Ω

0~19.99K

Ω

SM3D-R20

SM3D-R200

SM3D-R2K

SM3D-R20K

0~199.9K

Ω

0~1.999M

Ω

0~10.00M

Ω

SM3D-R200K

SM3D-R2M

SM3D-R10M

 Test  current

10mA

10mA

1mA

100uA

10uA

1uA

0.1uA

B

P

ower and input signal internal isolation model

J

Built-in CT isolation input

H

Hold function

B

Power and input signal internal isolation model

3

1

/

2  

MODEL

INPUT F.S

Dual slop integral method

Standard

AC Voltage

DC Voltage

AC/DC  Ampere

OTHER

--

RANGE

--

OTHER

--

0000

flash

(

for 4

1

/

2

)

divide volt.

divide volt.

divide volt.

divide volt.

divide volt.

Please put the tested cable through the C.T hole,The meter will display the
ampere , the meter was isolated with the circuit completely, SM3D-AA2-J
and SM5D- AA2-J  need to entwine the C.T hole 2 times.

For SM3D-R20 and SM3D-R200,please pay attention to the connecting
resistance influence to the measuring accuracy .

Model

Input range

Display range

SM3D-SV5

DC1~5V

SM3D-SV10

DC0~10V

SM3D-SA0.01

DC0-10mA

SM3D-SA0.02

DC4~20mA

SM3D-SX

Appointed signal

SM5D-SV5

DC1~5V

SM5D-SV10

DC0~10V

SM5D-SA0.01

DC0-10mA

SM5D-SA0.02

DC4~20mA

SM5D-SX

Appointed signal

0~±1999
the  decim al  point
position can be set
fre ely

0~±19999
the  decim al  point
position can be set
fre ely

Please  indicate  the  input  range ,and the  corresponding  display  range
information.

Reviews: