background image

Assembly Instructions

Shelter Type:

 SR1603

SR1603-02-260916-UK

Email : [email protected]

Web : www.shelters4less.co.uk

Tel : 0800 160 1002

Summary of Contents for SR1603

Page 1: ...Assembly Instructions Shelter Type SR1603 SR1603 02 260916 UK Email Sales shelters4less co uk Web www shelters4less co uk Tel 0800 160 1002...

Page 2: ...3 7 8 11 2 EXPLODED VIEW Fittings Bolt set M10 Nut Washer Black Cap T25 T50 AB1210 M10 x 60mm 25mm Tech screw 50mm Tech screw M10 X 100mmC3 Concrete Bolt Pack A B 40 40 80 80 136 66 13 Required 38 38...

Page 3: ...KET 109 x 100 x 80 5 7 RB1 BRACKET 110 x 46 8 8 L3 BRACKET 73 x 38 x 3 2 9 R3 CURVED RAFTER 1035 x 40 x 40 4 10 L1 BRACKET 95 x 45 x3 8 11 B4 BEAM 2080 x 40 x 40 2 12 P3 POST 1996 X 40 X 40 1 13 JF3 B...

Page 4: ...ignment Make sure corners are correctly aligned CB1 CB1 Step 1 Assemble S1 and S3 frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for the straight joints 4 Ple...

Page 5: ...A RB1 R3 L3 R3 RB1 L3 DETAIL A SCALE 1 4 L3 R3 Step 2 Attach the R3 end rafters using L3 brackets at the front and RB1 brackets for the rear 5...

Page 6: ...B T section DETAIL B SCALE 1 3 RB1 JF3 B4 P3 JF3 B4 P3 RB1 Step 3 Assemble the T section by attaching the B4 ties to the P3 post using RB2 and JF3 brackets 6...

Page 7: ...C L1 DETAIL C SCALE 1 6 L1 Step 4 Attach T section using L1 brackets...

Page 8: ...T3 FT1 FT3 FT1 Step 5 Move the shelter to its final position and make sure it is square and level Then attach the FT1 and FT3 foot brackets and use anchor bolts to secure the structure to the ground 8...

Page 9: ...y Sealing strips SS to the rafters and line up the PCE1 roof panels with the outside of the shelter and equally space the PCC1 panels between the outer panels Appy more sealing strips to the top of th...

Page 10: ...sing the 50mm Tech screws to secure the roof panels in place Then push the 2MD edge trim on to the bottom edge of the roof panels Fit Black plastic caps on exposed nuts and bolts and fit the square pl...

Page 11: ...HOLE CENTERS ON FEET 477 478 90 526 50 1035 1035 1035 1044 50 2070 2070 4180 1146 11 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 200mm oversized on all fo...

Page 12: ...BH1 1SA MAINTENANCE To ensure your product gives you many years of use we recommend that you THANK YOU FOR PURCHASING THIS PRODUCT Clean panels regularly with soapy water Ensure all fittings are tigh...