SW9 No. 1 ~ No. 3 Reserved
SW9 No. 4 Sort Copy function
Used for sort copy.
SW9 No. 5 ~ No. 7 Reserved
SW9 No. 8 Dial mode
Switch the type according to the telephone circuit connected to the
facsimile.
SW10 No. 1, No. 2 Reserved
SW10 No. 3 CNG detection
When setting to "1", the CNG signal detection function.
SW10 No. 4 Number of CNG detection
Used for detection of CNG in 2 or 3 pulses.
SW10 No. 5 Signal detect time in TEL/FAX mode
This setting is used for the time of the pseudo ringer off interval in the
TEL/FAX mode.
SW10 No. 6 Reserved
SW10 No. 7, No. 8 CNG detection time after ringing
CNG detection time after completion of ringing.
SW11 No. 1, No. 2 Reserved
SW11 No. 3 Time display format
When this switch is set to "0", time is displayed in 12-hour system.
When set to "1", 24-hour system.
SW11 No. 4 Date display format
Used to select date display/print formats.
0: DAY-Month-Year
1: Month-Day-Year
SW11 No. 5, No. 6 Pseudo ringing time at TEL/FAX automatic
switching mode
Choice is made as to how long to rumble the dummy ringer on TEL/
FAX automatic switching mode.
SW11 No. 7 Reserved
SW11 No. 8 CED detection time
It is effective to change this if detection error frequently occurs by set-
ting the CED automatic detection time.
SW12 No. 1 MH fixed
1: Both sending and reception are forcibly fixed to MH.
0: Adjusted to the performance of the other machine.
SW12 No. 2 ~ No. 5 Reserved
SW12 No. 6 Key tone
Used to toggle the key sound between on and off.
SW12 No. 7, No. 8 Reserved
SW13 No. 1 ~ No. 8 Reserved
SW14 No. 1 ~ No. 4 Reserved
SW14 No. 5 ~ No. 8 Modem Speed
Used to determine the initial modem speed. The default is
14400BPS(V.17). It may be necessary to program it to a slower speed
when frequent line fallback is encountered, in order to save the time
required for the fallback procedure.
SW15 No. 1 ~ No. 8 Reserved
Pauses can be inserted between telephone numbers of direct dial con-
nection. Selection of 4 sec or 2 sec pause is available.
SW16 No. 1 Digital cable equalizer for transmission
Digital cable equalizer for transmission
0: OFF
1: ON
SW16 No. 2, No. 3 Reserved
SW16 No. 4 Flash send time
Used to select length of flash.
SW16 No. 5, No. 6 Flash short time
Selects the flash send time when the flash send time of SW16 No. 4 is
set to short time.
SW16 No. 7, No. 8 Flash long time
Selects the flash send time when the flash send time of SW16 No. 4 is
set to long time.
SW17 ~ SW20 No. 1 ~ No. 8 Reserved
SW21 No. 1, No. 2 Line density selection
Used to set the transmission mode which is automatically selected
when the Resolution key is not pressed. In the copy mode, however,
the fine mode is automatically selected unless the Resolution key is
manually set to another mode.
SW21 No. 3 ~ No. 5 Communication results printout
It is possible to obtain communication results after each transaction.
Normally, the switch is set (No. 3: 0, No. 4: 0, No. 5: 1) so that the
communication result is produced only a communication error is
encountered. If No. 3 was set to 1, No. 4 was set to 1 and No. 5 was
set to 0, the communication result will be produced every time a com-
munication is done, even if the communication was successful. If No. 3
was set to 0, No. 4 to 1 and No. 5 to 0, the communication result will
be produced every transmission. Setting No. 3 to 1 No. 4 to 0 and No.
5 to 0 will disable this function. No transaction report will be printed. If
No. 3 was set to 0, No. 4 to 0 and No. 5 to 0, the communication result
is produced only after a memory transmission or when a communica-
tion error is encountered.
SW21 No. 6 Caller ID function
Used for Caller ID function.
SW21 No. 7 Activity report print
This soft switch is used to select: whether or not to print out the activity
report when the memory is full. An activity report can be printed when
the following key entry command is mode.
"FUNCTION ", "
↓
", "
↓
", "
→
"
After producing the activity report, all the data in the memory will be
cleared. When the switch function is set to "0" (no), the data in the
memory will be deleted from the oldest as it reaches the maximum
memory capacity.
SW21 No. 8 Daylight saving (Summer time)
Used to set YES/NO of holding function by the Hold key.