Sharp NU-SA Series Installation Manual Download Page 2

SIM425-002 

 

 

 

 

2

 

4.

 

PV  modules  produce  electricity  when  the  sufficient  sunlight  or  other 
sources  illuminate  the  module  surface.  When  the  modules  are 
connected  in  series,  voltage  is  cumulative.  When  the  modules  are 
connected in parallel, current is cumulative. As a result, a large-scale 
PV system can produce high voltage and current which could present 
an increased hazard and may cause serious injury or death. 

5.

 

Do  not  connect  the  PV  modules  directly  to  the  loads  such  as  motor 
since  the  variation  of  the  output  power  depending  on  the  solar 
irradiation causes damage for the connected motor. 

1: In the case of a brushless motor, the lock function becomes active      

and the hall IC is most likely to be damaged.  

2:  In  the  case  of  a  brush  type  motor,  the  coil  is  most  likely  to  be 

 

 

damaged. 

6.

 

In  case  of  snow  build-up,  snow  would  slide  easier  on  the  smooth 
surface  of  the  module  than  other  parts  of  the  roof.  Snow  may 
suddenly  slide,  fall  off  the  roof  and  hit  nearby  objects/areas.  Take 
preventive  measures  (e.g.  snow  stopper)  when  there  is  possible  risk 
such case would cause an injury or a damage. 

 

GENERAL SAFETY 

 

1.

 

Install PV modules and ground frames and other metal components in 
accordance with applicable codes and regulations. 

2.

 

PV modules should be installed and maintained by qualified personnel. 
Only  installation/service  personnel  should  have  access  to  the  PV 
module installation site. 

3.

 

Keep children away from PV modules. 

4.

 

Prior  to  installation,  do  not  store  modules  outdoors  or  in  a  damp 
environment to prevent glass from damage due to white efflorescence. 

5.

 

When  PV  modules  are  installed  on  roofs  or  any  other  structures 
above  ground,  appropriate  safety  practices  should  be  followed  and 
appropriate  safety  equipment  should  be  used  in  order  to  avoid 
possible  safety  hazards.  Note  that  the  installation  of  PV  modules  on 
some  roof types may  require the addition of fireproofing, as required 
by local building/fire codes. 

6.

 

Roof  mounted  PV  modules  are  to  be  mounted  over  a  fire  resistant 
roof. 

7.

 

Only  PV  modules  with  the  same  cell  size  should  be  connected  in 
series. 

8.

 

Follow all safety precautions of other components used in the system. 

9.

 

In order to avoid risk of injury or electrical shock, do not allow anyone 
to  handle  damaged  PV  modules  if  the  person  is  unqualified  or  has 
limited  knowledge  of  PV  modules.  Place  defective  PV  modules  in 
cartons  so  PV  cells  are  completely  shaded,  because  a  defective  PV 
module or module with broken glass may generate power even if it is 
removed from the system. 

10.

 

Avoid  uneven  shade  on  the  PV  module  surface.  Shaded  cells  may 
become hot (“hot spot” phenomenon) which may result in permanent 
damage to the module (e.g., solder joints may peel off). 

11.

 

Do not clean the glass surface with chemicals. Do not let water stay 
on  the  glass  surfaces  of  PV  modules  for  a  long  time.  This  creates  a 
risk of permanent damage to the glass, such as white efflorescence, 
otherwise known as “glass disease,” which may cause reduced power 
output. 

12.

 

To  avoid  dirt  accumulation  or  white  efflorescence  due  to  water 
accumulation, do not install PV modules horizontally (flat).  

13.

 

In  high  snow  load  regions,  appropriate  measures  are  to  be  taken  so 
that  PV  module  frames  (on  lower  edges  of  the  modules)  will  not  be 
damaged. 

14.

 

Do  not  expose  PV  modules  to  sunlight  concentrated  with  mirrors, 
lenses  or  other  means.  Turn  off  inverters  and  circuit  breakers 
immediately, should a problem occur. 

15.

 

The  maximum  open  circuit  voltage  must  not  be  greater  than  the 
specified  maximum  system  voltage.  Voltage  is  proportional  to  the 
number of PV modules in series and is affected by weather conditions. 
For  strings  connected  in  parallel  take  proper  measures  to  block 
reverse current flow. 

Following clauses with *) describe requirement 

for US market

 only

 

16.

 

*)  When  installing  PV  modules  in  a  readily  accessible  location,  the 
National  Electrical  Code  (NEC)  690.33  requires  installing  the 
additional  locking  sleeve  (Multi-Contact  part  #  PV-SSH4)  on  the 
connector. Note that this sleeve is not included with the module. This 

requirement  is  for  circuits  operating  in  excess  of  30  volts,  nominal, 
maximum system voltage for DC or 30 volts for AC circuits. 

18.

 

*)  Wiring  and  grounding  method  of  the  frame  of  arrays  shall  comply 
with the NEC, article 250. 

19.

 

*) Grounding shall be achieved through securement to the array frame. 
The  array  frame  shall  be  grounded  in  accordance  with  NEC,  article 
250. 

 

HANDLING SAFETY  

1.

 

Do  not  expose  the  PV  module  to  excessive  loads  on  the  surface  of 
the PV module or twist the frame. The glass may break. 

2.

 

Do  not  stand  or  step  on  the  PV  module.  The  glass  may  be  slippery, 
and there is a risk of injury or electric shock if glass is broken. 

3.

 

Do not hit or put excessive load on the glass or back sheet. PV cells 
may break. 

4.

 

To  avoid  damage  to  the  back  sheet,  do  not  scratch  or  hit  the  back 
sheet.  

5.

 

To avoid damage to the terminal box and electricity leakage or shock, 
do not hit the terminal box; do not pull the interconnect cables; do not 
scratch the interconnect cable. 

6.

 

Avoid  the  connector  from  scratching  or  impacting  the  back  sheet  of 
the module. 

7.

 

Install connector such that it is not exposed to direct sunlight. 

8.

 

Do not twist the interconnect cable excessively. 

9.

 

Never touch the end of the interconnect cables with bare hands when 
the  module  is  illuminated.  Cover  the  surface  of  module  with  cloth  or 
other  sufficiently  opaque  material  to  block  the  module  from  incident 
light  and  handle  the  wires  with  insulated  gloved  hands  to  avoid 
electric shock. 

10.

 

Do not drill holes in the frame. It may compromise the frame strength 
and cause corrosion of the frame. 

11.

 

Do  not  scratch  the  anodized  coating  of  the  frame  (except  for 
grounding  connection).  It  may  cause  corrosion  of  the  frame  or 
compromise the frame strength. 

12.

 

Do  not  touch  the  PV  module  with  bare  hands.  The  frame  of  the  PV 
module has sharp edges and may cause injury. Wear suitable gloves, 
such as leather gloves with padding in the palm and finger areas. 

13.

 

Do not drop the PV module or allow objects to fall on the PV module. 

14.

 

Do  not  lift  the  PV  module  by  only  one  side.  The  frame  may  bend. 
Always use two hands to lift and carry the PV module on the long side 
of the frame. 

15.

 

To  prevent  finger  prints  and/or  any  other  stains  on  the  glass,  do  not 
touch the anti-reflective coated glass. 

 

INSTALLATION SAFETY 

1.

 

Always wear protective head gear, insulating gloves and safety shoes 
with rubber soles. 

2.

 

Keep the PV module packed in the carton until installation. 

3.

 

Do  not  touch  the  PV  module  unnecessarily  during  installation.  The 
glass surface and the frame may be hot. There is a risk of burns and 
electric shock. 

4.

 

Do not work in rain, snow or windy conditions. 

5.

 

Due  to  the  risk  of  electrical  shock,  do  not  perform  any  work  if  the 
terminals of the PV module are wet. 

6.

 

Use insulated tools and do not use wet tools. 

7.

 

When  installing  PV  modules,  do  not  drop  any  objects  (e.g.,  PV 
modules or tools). 

8.

 

Make  sure  flammable  gasses  are  not  generated  or  present  near  the 
installation site. 

9.

 

Check  all  connections.  Insert  interconnect  connectors  fully  and 
correctly.  

10.

 

The  slack  interconnect  cable,  excluding  parts  such  as  connectors, 
should  be  securely  fastened  to  the  module  frame,  the  mounting 
racking  or  in  a  raceway  to  prevent  movement  of  the  interconnect 
cable over time. Cable support should be done in a way to avoid the 
connector from scratching or impacting the back sheet of the module. 

11.

 

Do not touch the terminal box and the end of the interconnect cables 
(connectors)  with  bare  hands  during  installation  or  under  sunlight, 
regardless of whether the PV module is connected to or disconnected 
from the system. 

12.

 

Do  not  unplug  a  connector  if  the  system  circuit  is  connected  to  an 

Summary of Contents for NU-SA Series

Page 1: ...se the lower edge of the module frame to deform Take necessary measures e g snow stopper to avoid possible damage 14 Periodically remove any overhanging snow and or ice from the module framework as it may cause deformation of the module frame GENERAL INSTRUCTIONS 1 INTRODUCTION Thank you for choosing SHARP photovoltaic PV module This Installation Manual contains essential information for the elect...

Page 2: ...ent for US market only 16 When installing PV modules in a readily accessible location the National Electrical Code NEC 690 33 requires installing the additional locking sleeve Multi Contact part PV SSH4 on the connector Note that this sleeve is not included with the module This requirement is for circuits operating in excess of 30 volts nominal maximum system voltage for DC or 30 volts for AC circ...

Page 3: ...igure 1 when connecting the modules to a battery or to other modules If not connected correctly the bypass diode s could be destroyed Maximum series configuration please refer to Table 1 This value is calculated under the condition of Voc at 40 C Maximum parallel configuration Parallel connection of each string shall be conducted with following two options Any other parallel connections are prohib...

Page 4: ...re mounted on should be rigid SHARP PV modules are designed to ensure optimal electrical performance under the condition that they are mounted on rigid support structures Deformation of support structure may damage PV module with its electric performance When mounting the module on structure ensure that no corner has a displacement of more than 2mm 0 08in per every 1000mm 39 37in of the diagonal f...

Page 5: ... fuse sizes and size of controls connected to the module output for US market Refer to Sec 690 8 of the National Electric Code for an additional multiplying factor of 125 percent 80 percent de rating which may be applicable Application Class This module is rated as Application class A according to IEC61730 Application class A means General access hazardous voltage hazardous power applications Modu...

Reviews: