IMPORTANT SAFETY INSTRUCTIONS 

This manual contains important safety instructions for the PV module that must be followed during the maintenance of PV 
modules. 

1)To reduce the risk of electric shock, do not perform any servicing unless you are qualified to do so. 
2)The installation must be performed by a certified installer/servicer to ensure system integrity and safety. 
3)Do not pull the PV cables. 
4)Do not touch any surface of module. 
5)Do not place/drop objects onto the PV modules. 
6)Do not disassemble or attempt to repair the PV module by yourself. 
7)Do not drop the PV module. 
8)Do not damage, pull, bend, or place heavy material on cables. 
9)Upon completion of any service or repairs, ask the installer/servicer to perform routine checks to determine that the PV 

modules are in safe and proper operating condition. 

10)When replacement parts are required, be sure the installer/servicer uses parts specified by the manufacturer with same 

characteristics as the original parts. Unauthorized substitutions may result in fire, electric shock, or other hazard. 

11)Consult your local building and safety department for required permits and applicable regulations. 

 
 
 
 
 
 

SHARP ELECTRONICS CORPORATION 

PHOTOVOLTAIC MODULE LIMITED WARRANTY

 

 
This Limited Warranty applies to photovoltaic modules manufactured by SHARP with the following model numbers: 

ND-U230C1 / ND-U224C1 / ND-U216C1 / ND- 224UC1 / ND-220UC1 / ND-216UC1 / ND-208UC1 / ND-200UC1 / 
NT-175UC1 / NT-170UC1 / NE-170UC1 / NE-165UC1

 

 
Limited Warranty For Materials or Workmanship: Sharp Electronics Corporation warrants to the first consumer purchaser 
that this Sharp brand product (the “Product”), when shipped in its original container, will be free from defective 
workmanship and materials, and Sharp agrees that for a period of one (1) year from the date of purchase by the consumer, 
that Sharp will, at its option, either repair the defect or replace the defective Product or part thereof with a new or 
remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.   
 
Limited Warranty For Power: The warranty period with respect to power output continues for a total of 25 years from date 
of purchase by the consumer, the first 10 years at 90% minimum rated power output and the balance of 15 years at 80% 
minimum rated power output.    This warranty is transferable when product remains installed in original location at the time 
of product warranty registration.   
 
This warranty does not apply to any alteration of the appearance of the Product that does not affect the performance or 
functionality of the Product, nor to the additional excluded item(s) set forth below nor to any Product, in Sharp’s sole 
discretion, the exterior of which has been damaged or defaced, which has been subjected to misuse, abnormal service or 
handling, or which has been altered or modified in design or construction.   
 
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide 
proof of purchase to the servicer.   
 
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. 
ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE 
LIMITED TO THE PERIOD(S) FROM THE DATE OF THE PURCHASE SET FORTH BELOW. Some states do not allow 
limitations on how long an implied warranty lasts, so the above limitation may not apply to you.   
 
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those 
described herein, or to extend the duration of any warranties beyond the time period described above on behalf of Sharp.   
 

Summary of Contents for ND-U230C1

Page 1: ...thal shock whether the PV modules are connected or not 4 PV modules produce electricity when sufficient sunlight or other light source illuminates the module When modules are connected in series voltage is cumulative When modules are connected in parallel current is cumulative PV systems can produce high voltage and current which could present an increased hazard and may cause serious injury or de...

Page 2: ...oves with padding in the palm and finger areas 14 Do not drop the PV module or allow objects to fall on the PV module 15 Do not lift the PV module by only one side The frame may bend Always use two hands to lift and carry the PV module on the long side of the frame 16 Some PV modules incorporate one or more support bars on the back of the module Do not mount or carry the PV module using the suppor...

Page 3: ...ions below In a connection of this type the hardware such as a star washer must score the frame surface to make positive electrical contact with the frame The ground wire must not be smaller than No 14 AWG 2 1 mm2 and should be sized according to the NEC Hardware used must be compatible with the mounting structure material to avoid galvanic corrosion If using the SHARP On Energy mounting system th...

Page 4: ...5 11 12 The modules may be mounted using clamps designed for solar modules as shown in Figures 5 Note that the clamp positions are important the clamp centerlines must be between 9 3 235 mm and 19 4 495 mm regarding ND series as shown in Figure 11 and 8 3 210mm and 18 5 470mm regarding NT NE series as shown in Figure 12 from the end of the module The module must be supported along the length of th...

Page 5: ... s Figure 12 NT NE series Figure 9 ND series u u u u Figure 12 NT NE series Figure 9 ND series Figure 10 NT NE series 8 3 210 mm g 18 5 470 mm Figure 11 ND series 9 3 235 mm e 19 4 495 mm Figure 13 ND series 9 3 235 mm s 19 4 495 mm 8 3 210 mm u 18 5 470 mm Figure 14 NT NE series ...

Page 6: ...m power Ipmax 7 66 A 7 54 A 7 48 A 7 25 A 7 04 A Maximum System Voltage 600 V 600 V 600 V 600 V 600 V Minimum Blocking diode 15 A 15 A 15 A 15 A 15 A Series Fuse 15 A 15 A 15 A 15 A 15 A NT 175UC1 NT 170UC1 NE 170UC1 NE 165UC1 Maximum Power Pmax 175 0 W 142 0 W 170 0 W 165 0 W Open Circuit Voltage Voc 44 4 V 43 2 V 43 2 V 43 1 V Short Circuit Current Isc 5 40 A 5 47 A 5 47 A 5 31 A Voltage at maxi...

Page 7: ...nship and materials and Sharp agrees that for a period of one 1 year from the date of purchase by the consumer that Sharp will at its option either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period s set forth below Limited Warranty For Power The warranty period with respect to ...

Page 8: ...improper voltage or power surges or abnormal environmental conditions such as acid rain or other pollution c the components in the construction base on which the module is mounted are defective d external corrosion mold discoloration or the like occurs e the product has been moved from its original installation f the model number or serial number of the product is altered removed or rendered illeg...